  "record_id": "00548c56a86551de",
  "title": "Industrial vacuum cleaner 216 E",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "Record type": "Equipment reference",
    "Manufacturer": "Nederman",
    "Model": "216 E",
    "Duty": "Dry industrial vacuuming",
    "Applications": "Dust, granulate, grit, fumes and swarf",
    "Installation": "Indoor",
    "Pre-separation": "Cyclonic",
    "Filter cleaning": "Reverse air pulse",
    "Maximum airflow": "460 m³/h",
    "Dust-bin volume": "47 L",
    "Filter area": "2.38 m²",
    "Hose length": "7.5 m",
    "Hose diameter": "51 mm",
    "Housing material": "Sheet metal",
    "Optional filtration": "HEPA filter",
    "Certification": "CE"
  },
  "summary": "Nederman 216 E is an indoor electric industrial vacuum for dry dust, granulate, grit, fumes and swarf. It combines cyclonic pre-separation with reverse-air-pulse filter cleaning and is listed at 460 m³/h maximum airflow, 47 L bin capacity, 2.38 m² filter area and a 7.5 m × 51 mm hose.",
  "sections": [
    {
      "heading": "Equipment role",
      "paragraphs": [
        "216 E is a portable, electrically powered dry-material collector for powder, dust, grit, granulate, fumes and swarf. The captured application examples include composite handling, construction and chemical-industry dry-material cleanup.",
        "Cyclonic pre-separation reduces the direct solids load on the main filter, while reverse-air-pulse cleaning is used to restore filter flow."
      ]
    },
    {
      "heading": "Technical data",
      "items": [
        "Maximum airflow: 460 m³/h.",
        "Dust-bin capacity: 47 L.",
        "Filter area: 2.38 m².",
        "Hose: 7.5 m long, 51 mm diameter.",
        "Installation: indoor; housing: sheet metal; certification: CE.",
        "Optional downstream filtration: HEPA filter."
      ]
    },
    {
      "heading": "Use and maintenance",
      "items": [
        "Use only for dry materials within the unit's qualified duty.",
        "Check the cyclone, hose and inlet for accumulated material that can reduce airflow.",
        "Operate the reverse-air-pulse cleaning method under the prescribed sequence.",
        "Empty the 47 L bin before overfill and inspect seals after reassembly.",
        "Select the HEPA option only after confirming the required filtration class and change procedure."
      ]
    },
    {
      "heading": "Safety boundary",
      "paragraphs": [
        "The captured page does not identify an explosion-protection rating. Do not collect combustible dust, hot material, reactive powder or hazardous fume without a documented suitability assessment for the entire vacuum system.",
        "Isolate electrical power before service and control operator exposure when emptying fine or hazardous material."
      ]
    }
  ],
  "updated_at": "2026-10-13T08:41:12.518Z"
}