RUPES ATEX HE Zone 22 turbine family

Technical family reference for RUPES ATEX-labelled HE centralized extraction turbines intended for Zone 22 installations. It records the published HE201, HE501 and HE901 performance values while keeping hazardous-area suitability separate from ordinary airflow sizing.

Record typeHazardous-area equipment-family reference
FamilyRUPES ATEX HE standard turbines
Published zoneATEX Zone 22
ModelsHE201, HE501 and HE901
Supply380 V three-phase
Power2.2, 3.0 or 5.5 kW
Maximum vacuum2900 mmH₂O
Flow capacity320, 390 or 550 m³/h
Filter area4, 4 or 8 m²
Dust container50 L
Working pressure6 bar

Published model data

HE2012.2 kW; 320 m³/h; 2900 mmH₂O; 4 m² filter; 2 tools; 65 dB(A); 130 kg
HE5013.0 kW; 390 m³/h; 2900 mmH₂O; 4 m² filter; 3 tools; 65 dB(A); 135 kg
HE9015.5 kW; 550 m³/h; 2900 mmH₂O; 8 m² filter; 5 tools; 70 dB(A); 170 kg

Shared equipment features

Hazardous-area qualification

The reviewed product family is labelled for ATEX Zone 22. That label alone does not determine suitability for every combustible dust or installation.