  "record_id": "392d4684863527dc",
  "title": "Air Purification Box CCD-1RC",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "Record type": "Air-purification unit",
    "Manufacturer": "Nederman",
    "Model": "CCD-1RC",
    "Application": "Light airborne dust and fumes",
    "Installation": "Indoor; free hanging",
    "Maximum airflow": "2,550 m³/h",
    "Filter efficiency": "95%",
    "Noise level": "75.6 dB(A)",
    "Maximum filtered-media temperature": "80 °C",
    "Filter cleaning": "One-way replaceable filter",
    "Certification": "CE"
  },
  "summary": "Nederman CCD-1RC is a free-hanging indoor air-purification box for controlling light airborne dust and fumes in a contaminated air stream. Its one-way filter is rated at 95% efficiency with a maximum airflow of 2,550 m³/h.",
  "sections": [
    {
      "heading": "Application",
      "paragraphs": [
        "CCD-1RC is designed for free-hanging indoor installation where light airborne dust or fumes must be recirculated through a local purification unit. It is not described as a source-capture hood or a heavy-dust collector."
      ],
      "items": [
        "Applications: dust and fumes.",
        "Installation: indoor, free hanging.",
        "Filter arrangement: one-way filter.",
        "Certification: CE."
      ]
    },
    {
      "heading": "Verified performance",
      "items": [
        "Maximum airflow: 2,550 m³/h.",
        "Filter efficiency: 95%.",
        "Noise level: 75.6 dB(A).",
        "Maximum temperature of the filtered medium: 80 °C."
      ],
      "paragraphs": [
        "The published efficiency does not identify the test particle size or standard on the captured page. Suitability for a regulated contaminant therefore requires the applicable exposure limit and filtration test basis."
      ]
    },
    {
      "heading": "Positioning and use",
      "items": [
        "Suspend the unit within the contaminated-air circulation zone while preserving service access.",
        "Avoid placing supply or return paths where clean air immediately short-circuits back to the inlet.",
        "Check that the supporting structure can carry the unit and vibration loads.",
        "Use source extraction when the process requires capture before contaminants enter the breathing zone."
      ]
    },
    {
      "heading": "Filter management",
      "paragraphs": [
        "The one-way filter is replaced rather than regenerated. Pressure loss, airflow or a site maintenance interval should be used to determine replacement before performance degrades."
      ],
      "items": [
        "Isolate electrical power before opening the unit.",
        "Contain the used filter according to the collected contaminant.",
        "Inspect inlet and outlet grilles and remove obstructions.",
        "Confirm airflow after filter replacement."
      ]
    },
    {
      "heading": "Safety boundaries",
      "paragraphs": [
        "The page identifies light dust and fumes but does not establish suitability for combustible dust, toxic gas, oxygen-deficient spaces or high-temperature process exhaust. These duties require a separately qualified system."
      ]
    }
  ],
  "updated_at": "2026-10-13 06:36:00"
}