  "record_id": "70054998bb34ec38",
  "title": "FilterBox Wall",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "manufacturer": "Nederman",
    "family": "FilterBox Wall",
    "variants": "Wall M; Wall A; Wall A+",
    "maximum_airflow": "1,300 m³/h",
    "filter_area": "13 m²",
    "filter_efficiency": "99%",
    "dustbin_volume": "15 L",
    "extraction_arm_diameter": "160 mm",
    "noise_level": "60 dB(A) without fan; 66 dB(A) N24; 74 dB(A) N27",
    "compressed_air": "DIN ISO 8573-1 class 5/5/4 at 7 bar",
    "protection_class": "IP54",
    "installation": "indoor wall mounting",
    "certification": "CE; W3 under EN 15012-1"
  },
  "summary": "FilterBox Wall is a wall-mounted extraction family offered as manual Wall M, automatic Wall A and nanofibre Wall A+ versions. Units can be supplied with a fan or connected to an external fan system, supporting multiple extraction stations without occupying floor space.",
  "sections": [
    {
      "heading": "Variant comparison",
      "rows": [
        [
          "Wall M",
          "Manually cleaned polyester filter with low-airflow alarm"
        ],
        [
          "Wall A",
          "Automatically cleaned polyester filter with pressure-drop control"
        ],
        [
          "Wall A+",
          "Extra-large automatically cleaned nanofibre filter for frequent welding"
        ]
      ]
    },
    {
      "heading": "Fan and installation choices",
      "paragraphs": [
        "The family is supplied with a wall bracket and can use an attached fan or an external fan and contactor. External-fan layouts can connect multiple FilterBox units to a shared extraction installation."
      ],
      "items": [
        "Maximum family airflow is 1,300 m³/h.",
        "The 160 mm arm connection feeds a 13 m² filter and 15 L dust bin.",
        "Combustible dust, combustible gas and explosive atmospheres are outside the permitted duty."
      ]
    },
    {
      "heading": "Cleaning and service",
      "paragraphs": [
        "Manual and automatic variants use different controls. Automatic versions monitor pressure drop and initiate motorised cleaning; welding-fume configurations require compressed air."
      ],
      "items": [
        "Verify the selected fan against the stated noise level and system resistance.",
        "Inspect the wall bracket and fasteners for the complete operating load.",
        "Keep the damper, filter seals and 15 L bin closed during cleaning and servicing."
      ]
    }
  ],
  "updated_at": "2026-10-13T10:38:11.042Z"
}