  "record_id": "7c49760eb1da496a",
  "title": "FilterBox 10A",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "Record type": "Equipment reference",
    "Manufacturer": "Nederman",
    "Model": "FilterBox 10A",
    "Applications": "TIG, MIG and MAG welding excluding high-alloy work; grinding",
    "Installation": "Indoor, mobile or fixed",
    "Maximum airflow": "1,000 m³/h (600 CFM)",
    "Filter area": "13 m²",
    "Listed filter efficiency": "99%",
    "Filter class": "M6 (EN 779); MERV 11 (ASHRAE 52.2-2017)",
    "Welding-fume approval": "W3 according to EN 15012-1",
    "Dust-bin volume": "15 L",
    "Extraction-arm diameter": "160 mm",
    "Noise level": "66 dB(A)",
    "Compressed air": "DIN ISO 8573-1 class 5/5/4 at 7 bar",
    "Ingress protection": "IP54",
    "Excluded service": "Combustible dust and combustible gases"
  },
  "summary": "Nederman FilterBox 10A is an automatically cleaned indoor mobile or fixed extractor for light-to-medium welding fume and grinding dust. It provides 1,000 m³/h airflow, 13 m² filter area, 99% listed efficiency, a 15 L dust bin and 66 dB(A) sound level, with W3 approval for applicable welding fume service.",
  "sections": [
    {
      "heading": "Configuration and use",
      "paragraphs": [
        "FilterBox 10A combines an N24 fan, automatic filter-cleaning controls and an indoor dust bin in a mobile wheeled or fixed-mount arrangement. It is intended for intermittent light-to-medium welding fume and grinding-dust capture.",
        "The control system monitors pressure drop, warns when airflow is low and initiates a motorized cleaning sequence. Welding configurations require compressed-air cleaning; an optional HEPA stage can provide additional downstream filtration."
      ]
    },
    {
      "heading": "Technical data",
      "items": [
        "Maximum airflow: 1,000 m³/h (600 CFM).",
        "Filter area: 13 m²; listed efficiency: 99%.",
        "Dust bin: 15 L; extraction-arm diameter: 160 mm.",
        "Noise level: 66 dB(A); ingress protection: IP54.",
        "Compressed-air quality: DIN ISO 8573-1 class 5/5/4 at 7 bar."
      ]
    },
    {
      "heading": "Application limits",
      "paragraphs": [
        "The captured page lists TIG, MIG and MAG welding except high-alloy work, plus grinding. W3 approval is stated according to EN 15012-1; selection still depends on fume composition, source-capture geometry and local exposure limits.",
        "This model is explicitly excluded from environments containing combustible dust or gas and must not be used to filter combustible dust or gas."
      ]
    },
    {
      "heading": "Maintenance",
      "items": [
        "Observe the pressure-drop indication and low-airflow alarm.",
        "Use the correct mechanical or combined pneumatic cleaning configuration for the duty.",
        "Isolate the fan and compressed air before filter or bin service.",
        "Use the dust-free replacement and emptying procedure, and dispose of collected material according to its hazard classification."
      ]
    }
  ],