  "record_id": "89da2db8e00670f8",
  "title": "Industrial vacuum cleaner 500A EX - reliable wet suction unit",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "Record type": "Equipment reference",
    "Manufacturer": "Nederman",
    "Model": "500A EX",
    "Duty": "Wet extraction of liquids and sludge",
    "Container system": "Single container with bottom drain",
    "Container volume": "208 L",
    "Material": "AISI 304 stainless steel",
    "Overfill protection": "Float ball stops suction when full",
    "Compressed-air consumption": "3 m³/min",
    "Certifications": "CE; EX",
    "ATEX gas marking": "II 2G Ex h IIC T60°C (T6) Gb",
    "ATEX dust marking": "II 2D Ex h IIIC T60°C (T6) Db",
    "Handling features": "Lifting lugs and bottom drain valve"
  },
  "summary": "Nederman 500A EX is a compressed-air industrial vacuum for liquids and sludge, built in AISI 304 stainless steel with a 208 L container, bottom drain and float overfill shutoff. The captured configuration consumes 3 m³/min compressed air and carries gas- and dust-zone ATEX markings for 60 °C maximum surface-temperature class.",
  "sections": [
    {
      "heading": "Wet-collection duty",
      "paragraphs": [
        "500A EX is a compressed-air vacuum for collecting flammable liquids and sludge into a single 208 L container. A bottom drain supports controlled discharge, and an internal float stops suction when the vessel reaches its liquid limit.",
        "AISI 304 stainless-steel construction and lifting lugs support industrial handling, but compatibility must still be checked against the collected liquid."
      ]
    },
    {
      "heading": "Captured technical data",
      "items": [
        "Container volume: 208 L.",
        "Compressed-air consumption: 3 m³/min.",
        "Container material: AISI 304 stainless steel.",
        "Overfill control: float-operated suction stop.",
        "Discharge: bottom drain valve.",
        "Certifications shown: CE and EX."
      ]
    },
    {
      "heading": "Explosion-protection marking",
      "paragraphs": [
        "The captured configuration lists II 2G Ex h IIC T60°C (T6) Gb for gas atmospheres and II 2D Ex h IIIC T60°C (T6) Db for dust atmospheres.",
        "The marking applies only when the exact equipment configuration, accessories, bonding, compressed-air supply and collected substance remain within the certified conditions. It is not a blanket authorization for every flammable liquid."
      ]
    },
    {
      "heading": "Operation and maintenance",
      "items": [
        "Verify chemical compatibility with AISI 304, seals, hose and drain components.",
        "Bond and ground the complete collection path as required by the hazardous-area assessment.",
        "Test the float shutoff and inspect the drain valve before each wet-collection task.",
        "Depressurize the pneumatic supply and isolate the unit before opening or draining.",
        "Use the lifting lugs and rated handling method; never lift an unverified full container."
      ]
    }
  ],
  "updated_at": "2026-10-13T08:41:12.518Z"
}