  "record_id": "ae235020663ec074",
  "title": "Nederman FlexFilter EX Combustible-Dust Collector",
  "kind": "product",
  "company": "Nederman",
  "parameters": {
    "Maximum airflow": "1,600 m³/h per filter",
    "Filter area": "12 m² per filter",
    "Filter cleaning": "Reverse air pulse",
    "Dust bin volume": "70 L",
    "Installation": "Outdoor",
    "Suitable dust classes": "St1 and St2",
    "Maximum Pmax": "10 bar",
    "Minimum ignition energy": "Greater than 1 mJ",
    "Minimum ignition temperature": "Greater than 205 °C",
    "ATEX marking": "II 3D Ex h IIIC T130°C Dc, -10°C ≤ Ta ≤ 40°C",
    "Directive": "2014/34/EU",
    "Material": "Sheet metal"
  },
  "summary": "FlexFilter EX is a modular outdoor high-vacuum collector for combustible dust, fumes, grit and granulate. The enclosure is designed for explosion overpressure relief and uses earth-bonded modules, EX-classified electrical equipment and reverse-air-pulse filter cleaning.",
  "sections": [
    {
      "heading": "Explosion-protection design",
      "paragraphs": [
        "The collector uses an explosion-relief panel to direct overpressure and flame propagation toward a designated safe area. Modular sections are electrically bonded, and the electrical components are classified for combustible-dust service.",
        "A control filter is supplied so that a non-EX vacuum unit can be used in the overall system when the complete installation is engineered accordingly."
      ]
    },
    {
      "heading": "Permitted dust properties",
      "items": [
        "Dust explosion class: St1 or St2.",
        "Maximum explosion pressure Pmax: 10 bar.",
        "Minimum ignition energy: above 1 mJ.",
        "Minimum ignition temperature: above 205 °C."
      ]
    },
    {
      "heading": "Collection and discharge",
      "paragraphs": [
        "Each filter module is rated for up to 1,600 m³/h and provides 12 m² of filter area. Reverse-air pulses clean the filters.",
        "Collected material can discharge into the standard 70 L bin with an antistatic bag; an automatic conductive bulk-bag arrangement is available for larger systems. Explosion zoning, isolation and venting require project-specific engineering."
      ]
    }
  ],
  "updated_at": "2026-10-13"
}