  "record_id": "bd9f4c0a0615ab4a",
  "title": "Combustible dust control for grinding and polishing",
  "kind": "reference",
  "company": "Nederman",
  "parameters": {
    "Record type": "Process and safety reference",
    "Primary concern": "Combustible dust",
    "Relevant processes": "Grinding, polishing and blasting",
    "Typical risk locations": "Process source, ducts, collectors, surfaces and concealed spaces",
    "Control sequence": "Capture, contain and clean",
    "Equipment framework": "ATEX 2014/34/EU",
    "Workplace framework": "ATEX 1999/92/EC",
    "Assessment": "Site- and material-specific"
  },
  "summary": "Technical reference for recognizing and controlling combustible dust generated by grinding, polishing and related material-removal processes. It organizes the hazard review around material screening, area classification, source capture, containment, housekeeping and verification of explosion-protection measures.",
  "sections": [
    {
      "heading": "Why fine dust changes the risk",
      "paragraphs": [
        "Finely divided material has much more exposed surface area than the same material in bulk form, allowing combustion to accelerate when an ignitable concentration and ignition source coincide.",
        "Grinding, polishing and blasting can generate suspended clouds and settled layers. Deposited dust is not benign: disturbance can re-entrain it and contribute to a secondary event."
      ]
    },
    {
      "heading": "Materials and process review",
      "items": [
        "Identify every material entering the process, including coatings, residues and mixed-material streams.",
        "Obtain representative dust test data when combustibility or explosion severity is unknown.",
        "Map normal and abnormal release points around tools, transfer locations, ducts, collectors and waste containers.",
        "Classify hazardous areas using the applicable workplace framework; do not infer a zone from dust visibility alone."
      ]
    },
    {
      "heading": "Capture, contain and clean",
      "rows": [
        [
          "Capture",
          "Collect dust as close as practical to the generation point using an application-matched hood, shroud or tool connection."
        ],
        [
          "Contain",
          "Keep dust within sealed, conductive and correctly designed ducting and collection equipment; manage leaks and pressure relief according to the hazard design."
        ],
        [
          "Clean",
          "Use a documented housekeeping method for floors, beams, cable trays and concealed ledges; avoid methods that disperse deposits into the air."
        ]
      ]
    },
    {
      "heading": "Equipment and management controls",
      "items": [
        "Select collectors, fans, filters, isolation devices and explosion-protection measures from the tested dust properties and classified zone.",
        "Control ignition sources, static electricity, hot particles and incompatible material mixing.",
        "Inspect differential pressure, duct condition, seals, containers and housekeeping effectiveness on a defined schedule.",
        "Train operators to recognize abnormal dust release, loss of extraction and unsafe waste handling.",
        "ATEX equipment and workplace directives provide a framework in relevant jurisdictions, but final compliance and protection design require a competent site-specific assessment."
      ]
    }
  ],
  "updated_at": "2026-10-12T21:43:00Z"
}