POLISHX

Success Case: Polishing the Inner Channel of UHP Valves │ DLyte

For ultrahigh-purity valve passages, a DLyte PRO500 dry-electropolishing route replaced abrasive-flow finishing with machining, automated finishing and post-dip cleaning. The case records 64 valves in 29 minutes, an acceptance target of Ra 0.15 µm, and a reported final roughness below Ra 0.05 µm on internal and external surfaces.

Record typeApplication case study
ProcessDry electropolishing with DLyte PRO500
WorkpieceUltrahigh-purity valve inner channels
ApplicationsSemiconductor, chemical, food, pharmaceutical and gas systems
Acceptance targetRa 0.15 µm
Reported final roughnessRa <0.05 µm
Recorded batch size64 pieces
Recorded process time29 min per batch
Revised workflowMachining, DLyte finishing, post-dip cleaning
Former processAbrasive flow machining
Surface requirementsUniform bright finish; no scratches, pits, burrs, dull areas or stains

Application objective

The case concerns internal passages of ultrahigh-purity and high-purity valves used in controlled gas service. Roughness and finishing defects can promote turbulence, particle generation and corrosion.

The stated acceptance target was Ra 0.15 µm with uniform brightness and no scratches, pitting, burrs, dull areas or stains. The case separately reports a final roughness below Ra 0.05 µm; these are recorded as target and result, not treated as interchangeable values.

Process route and capacity

The former abrasive-flow process required individual treatment, part-specific tooling and an additional passivation step. It also had limited access to blind holes and complex internal features.

The revised route uses machining, a DLyte PRO500 finishing cycle and post-dip cleaning. A batch of 64 parts was reported finished in 29 minutes.

Inspection and qualification

Cleanliness and safety

Ultrahigh-purity service requires a validated downstream cleaning and cleanliness-verification procedure. The recorded polishing cycle does not by itself certify a valve for a particular gas, pressure or purity class.

Maintain electrolyte condition and fixture contact, prevent alloy cross-contamination, and apply the current chemical, electrical and waste-handling controls.