POLISHX
RUPES HE centralized turbine family
Technical family reference for RUPES HE centralized dust-extraction turbines, including the 2.2–5.5 kW standard range and inverter-equipped 3–15 kW systems. It compares power, flow, vacuum, filter area, tool capacity and installation envelope without merging the individual models into one SKU.
| Record type | Equipment-family technical reference |
|---|
| Family | RUPES HE centralized turbines |
|---|
| Process | Extraction of micro-dust from sanding and industrial operations |
|---|
| Standard models | HE201, HE501 and HE901 |
|---|
| Inverter models | HE501i, HE901i, HE1301i, HE1801i, HE1901i and HE2001i |
|---|
| Supply | 380 V three-phase |
|---|
| Power range | 2.2–15 kW |
|---|
| Maximum flow range | 320–1300 m³/h |
|---|
| Maximum vacuum range | 2900–3500 mmH₂O |
|---|
| Dust container | 50 L |
|---|
| Working pressure | 6 bar |
|---|
Standard 2.2–5.5 kW range
| HE201 | 2.2 kW; 320 m³/h; 2900 mmH₂O; 4 m² filter; 2 tools; 65 dB(A); 130 kg |
|---|
| HE501 | 3.0 kW; 390 m³/h; 2900 mmH₂O; 4 m² filter; 3 tools; 65 dB(A); 135 kg |
|---|
| HE901 | 5.5 kW; 550 m³/h; 2900 mmH₂O; 8 m² filter; 5 tools; 70 dB(A); 170 kg |
|---|
Inverter range
| HE501i | 3.0 kW; 420 m³/h; 2900 mmH₂O; 4 tools |
|---|
| HE901i | 5.5 kW; 600 m³/h; 2900 mmH₂O; 6 tools |
|---|
| HE1301i | 7.5 kW; 750 m³/h; 2900 mmH₂O; 8 tools |
|---|
| HE1801i | 15 kW; 1000 m³/h; 3500 mmH₂O; 11 tools |
|---|
| HE1901i | 11 kW; 1100 m³/h; 3200 mmH₂O; 13 tools |
|---|
| HE2001i | 15 kW; 1300 m³/h; 3500 mmH₂O; 16 tools |
|---|
Filtration and maintenance features
- Cyclonic pre-filtration protects the cartridge stage.
- Rotor Jet automatic cleaning and manual cleaning are listed across the reviewed HE ranges.
- The standard family page reports 99.5% filtration efficiency for 0.3 µm micro-dust and up to 20,000 operating hours without maintenance; these are manufacturer-reported family claims, not site guarantees.
- Integrated monitoring displays pump hours, filter hours and installation notices.
System sizing
- Size by simultaneous tool count and measured airflow demand, not motor power alone.
- Include duct pressure loss, hose diameter, branch balancing and reserve capacity in the design calculation.
- Verify noise, electrical supply, compressed-air service for filter cleaning and container access at the installation location.
- Confirm dust combustibility and required explosion protection before choosing a non-ATEX or ATEX variant.