This process case addresses mixers and agitators used with food, pharmaceutical, chemical and cosmetic products. The reported dry electrolytic route reduced an initial average roughness of 1.5 µm to below 0.1 µm at eight measurement points, processing eight pieces in 180 minutes.
| Manufacturer | GPAINNOVA / DLyte |
|---|---|
| Record type | Process application case |
| Workpieces | Mixers and agitators |
| Process time | 180 minutes per batch |
| Batch capacity | 8 pieces |
| Initial average roughness | Ra 1.5 µm |
| Intermediate roughness | Ra 0.9 µm |
| Final roughness | Ra below 0.1 µm |
| Measurement locations | 8 points |
The application sought a clean, low-friction and corrosion-resistant contact surface to reduce adhesion of high-viscosity pharmaceutical and cosmetic products. Consistency matters because uneven manual finishing can create premature-failure or cross-contamination risks.
The micrometre and microinch values are retained as reported. The case does not specify the instrument, cutoff or filter settings, so the values should not be treated as a metrology procedure.
| Initial average | Ra 1.5 µm (60 µin) |
|---|---|
| After intermediate reduction | Ra 0.9 µm (35 µin) |
| Final reported result | Ra below 0.1 µm (11 µin) |
| Sampling | Eight measurement points across the surface |
The result combines the selected equipment, holder arrangement, electrolyte and parameter set. Food- or pharmaceutical-grade acceptance still requires the manufacturer’s validation and the applicable hygiene documentation.
| Previous steps | Soft-disc polishing plus liquid electropolishing |
|---|---|
| Replacement | DryLyte finishing route |
| Batch capacity | 8 pieces |
| Batch duration | 180 minutes |
POLISHX technical profile · 2026-10-13 15:36:08