  "record_id": "ef144daab73cfef6",
  "title": "FilterBox 12M",
  "kind": "product",
  "company": "Nederman",
  "parameters": {
    "manufacturer": "Nederman",
    "model": "FilterBox 12M",
    "maximum_airflow": "1,200 m³/h (700 CFM)",
    "filter_area": "13 m²",
    "filter_efficiency": "99%",
    "filter_class": "M6 (EN 779); MERV 11 (ASHRAE 52.2:2017)",
    "welding_fume_class": "W3 under EN 15012-1",
    "dustbin_volume": "15 L",
    "extraction_arm_diameter": "160 mm",
    "noise_level": "74 dB(A)",
    "compressed_air": "DIN ISO 8573-1 class 5/5/4 at 7 bar",
    "protection_class": "IP54",
    "installation": "indoor; mobile or fixed mount",
    "fan": "N29"
  },
  "summary": "Nederman FilterBox 12M is a manually cleaned indoor extractor for medium-to-heavier welding fumes and non-combustible grinding dust. Its N29 fan supplies up to 1,200 m³/h through a 13 m² M6/MERV 11 filter, with a 15 L dust bin and 160 mm extraction-arm connection.",
  "sections": [
    {
      "heading": "Operating range",
      "paragraphs": [
        "The 12M is intended for medium-frequency MMA stick-welding fume, excluding high-alloy duty, and for non-combustible grinding dust. Its N29 fan raises the maximum airflow to 1,200 m³/h."
      ],
      "items": [
        "The W3 welding-fume class is third-party tested under EN 15012-1.",
        "An audible alarm identifies insufficient airflow.",
        "It must not collect combustible dust or gas and must not operate in a combustible atmosphere."
      ]
    },
    {
      "heading": "Filter arrangement",
      "paragraphs": [
        "The 13 m² standard filter is M6/MERV 11 and has a stated efficiency of 99%. Filter cleaning is started manually: dust configurations use mechanical action, while welding-fume duty requires combined mechanical and compressed-air cleaning."
      ],
      "rows": [
        [
          "Dust container",
          "15 L"
        ],
        [
          "Arm connection",
          "160 mm"
        ],
        [
          "Noise level",
          "74 dB(A)"
        ],
        [
          "Compressed air",
          "Class 5/5/4 at 7 bar"
        ],
        [
          "Optional final stage",
          "HEPA filter"
        ]
      ]
    },
    {
      "heading": "Routine service",
      "paragraphs": [
        "The cleaning damper, dust-controlled filter change and integrated silencer are designed to keep collected material within the unit during normal maintenance."
      ],
      "items": [
        "Respond to the airflow alarm before continuing production.",
        "Check the compressed-air quality and pressure for welding use.",
        "Inspect the bin, filter seals and arm connection after every cleaning cycle."
      ]
    }
  ],
  "updated_at": "2026-10-13T10:36:22.062Z"
}