{
  "title": "AxioImager Vario - long brochure",
  "kind": "document",
  "company": "Allied High Tech Products",
  "category": "Metrology & quality control",
  "parameters": {
    "Language": "English",
    "Captured": "2026-10-17",
    "Document type": "downloads",
    "PDF pages": 16
  },
  "language": "en",
  "source_url": "https://www.alliedhightech.com/Media/Default/EquipmentBrochures/AxioImager%20Vario%20-%20long%20brochure.pdf",
  "content_html": "<p>AxioImager Vario - long brochure</p><p><a href=\"/files/allied-file-58cccb5294e55a2a98999c1b/AxioImager%20Vario%20-%20long%20brochure.pdf\">Open original PDF</a></p><details><summary>Full searchable text · 16 pages</summary><p>Refer to the original PDF for tables, figures and page layout.</p><pre style=\"white-space:pre-wrap\">Page 1\nMaximum stability and precision for large samples \nin materials analysis and quality control.\nM ic ro s c o py  f ro m  C a r l  Z ei s s\nAxio Imager Vario\nDedicated to Large Sample Analysis\n\n\nPage 2\n2\nIn materials microscopy the size of the sample space is one \nof the determining criteria when it comes to quality testing, \nquality assurance and materials analysis as well as to the \ndevelopment of future materials.\nAxio Imager Vario, the new addition to the tried-and-tested \nAxio Imager system series does justice to these demands \n– with consistently high optical performance, functionality \nand stability.\nAxio Imager Vario stands for maximum precision combined \nwith the largest possible sample space – in research, develop-\nment and quality assurance – involving solar cells, wafers or \nﬂat panel displays, for example.\nAt a glance –  \nThe outstanding features of Axio Imager Vario:\n•  Stable column design\n•  Impressive sample space with vertical extension  \nup to 254 mm and sample travel range up to 300 mm\n•  Nosepiece focus with step-size resolution up to 10 nm\n•  Excellent optics with outstanding contrast \nfor the best resolution\n•  Reﬂected-light illuminator with apochromatically \ncorrected ﬁeld lens\n•  Maximum precision and reproducibility \nthrough motorized components\nExceeds all  \nExpectations\n \nTitle:\nMono-crystalline silicon solar cell\nCircular Differential Interference Contrast\nEC Epiplan-APOCHROMAT 50x / 0.95\nRight:\nAxio Imager.A2 Vario with MARC control unit and \nAxio Imager.Z2 Vario with docking station and  \ntransmitted-light module.\n\n\nPage 3\n3\n\n\nPage 4\n4\nWell-thought-out Components –\nPerfectly Adapted to your Requirements\nThe column – High level stability\nA column with aluminum base plate forms a stable basis for \nthe Axio Imager Vario microscope, while the precise guides \nthat have been integrated into the column allow exact ad-\njustment of the sample space in the z-direction – from a \nheight of 0 to a maximum of 254 mm – according to the \nobjects being examined. Thanks to the lockable height stop, \nthe sample is reliably protected against damage. \nThe nosepiece focus – \nReliable focus and repeat accuracy \nAs the sample is brought into focus by moving the nose-\npiece up and down, it is not necessary to move the sample \nitself. This means, particularly in the case of heavy samples, \nthat it is possible to guarantee consistent focus and  repeat \naccuracy. Both stand variants – Axio Imager.A2 Vario and \nAxio Imager.Z2 Vario – are equipped with a motorized \nnosepiece focus, which has a 5 mm stroke and a step-size \nresolution of 25 or 10 nm.\nThe sample is brought into focus simply by moving  \nthe nosepiece up and down.\nAvailable as an option: manual transmitted-light module, suitable for \nKöhler illumination, for all common contrasting techniques.\nStable column design: \nvibration-free working \n5 mm\nAxio Imager Vario offers a ﬂexible system platform for research,\ntesting and development involving large material samples in areas  \nsuch as the solar, ﬂat panel and wafer industries. \nOperating elements for precise adjustment of the microscope module \nin the z-direction and lockable height stop.\n\n\nPage 5\n5\nThe stages and sample holders – The perfect basis\nDepending on the application, four different sample stages \nfor reﬂected-light and transmitted-light can be selected:\n•  manual stage with 200 mm travel range for  \nreﬂected-light and transmitted-light\n•  manual stage with 300 mm travel range for  \nreﬂected-light\n•  scanning stage with 200 mm travel range for  \nreﬂected-light and transmitted-light\n•  scanning stage with 300 mm travel range for  \nreﬂected-light and 200 mm travel range for  \ntransmitted-light\nThe manual stages are equipped with a coupler which can \nbe used to switch between the regular x-y drive and a \nhandle for rapid movement. It is possible to control the \nscanning stages with a repeat accuracy of 1 μm either via \nthe optional x/y drive on the Docking Station, via a separate \njoystick or using the PC. Numerous different insert plates \nand sample holders such as chucks for different wafer sizes, \nensure the ﬂexibility needed to be able to analyze the wid-\nest possible range of materials reliably. In the case of par-\nticularly tall samples, the sample stage can be dispensed \nwith entirely.\nThe transmitted-light module – Light from below\nA manual transmitted-light module suitable for Köhler illu-\nmination is available as an option for all common contrast-\ning techniques. This module can be equipped with halogen \nor LED illumination. In addition to a luminous ﬁeld dia-\nphragm, it also has a switchable diffusion screen, as well \nas an insert for a double ﬁlter wheel to hold neutral-density \nﬁlter sets. Four different condensers are available.\n\n\nPage 6\n6\nThe Microscope Modules\nPerfectly Equipped – Manual or Motorized\nAxio Imager.A2 Vario\nThe partially motorized microscope module Axio Imager.A2 Vario \noffers a solid base for measurement, analysis and docu-\nmentation in the area of materials microscopy. It is the \nright choice for applications where, although a large sample \nspace is required, no motorization is necessary – for chang-\ning the contrasting technique or magniﬁcation, for example. \nLight intensity and the motorized nosepiece focus (with 25 \nnm step-size resolution) can be adjusted conveniently us-\ning the freely positionable MARC (Manual Rotary Control) \ncontrol unit or PC, while coding of the key components al-\nlows essential microscope parameters to be adopted by the \nAxioVision software. The objective and total magniﬁcation, \ncontrasting techniques and brightness settings are stored \nand can be retrieved at any time.\nWhether for manual or motorized microscopy – \nwith its three available modules,   \nAxio Imager Vario offers the right solution  \nfor every analysis need.\n\n\nPage 7\n7\nAxio Imager.Z2 Vario\nThe powerful Axio Imager.Z2 Vario microscope module \nis fully motorizable and therefore the perfect system for \ncomplex applications and challenging tasks that demand a \nhigh degree of automation. Your work is made considerably \neasier thanks to the motorized reﬂected-light beam path, \nwhich allows all light and contrast settings to be precisely \nreproduced. All the motorized components of the micro-\nscope module can be controlled via the docking station \n(which is also freely positionable) or PC – ensuring a high \ndegree of operating comfort and reproducibility. The inte-\ngrated user administration also means that work can be \nmanaged simply and clearly in a multi-user environment. \nUse of the MARC control unit is also an option.\nIn addition to reﬂected light, both Axio Imager.A2 Vario and Axio Imager.Z2 Vario \nmicroscope modules can be equipped with the manual transmitted-light \nunit and can be freely combined with the sample stages available.\nAxio Imager.Z2 Vario without focus\nAxio Imager.Z2 Vario without focus is the third microscope module avail-\nable. Apart from the nosepiece focus, it offers the same functionality as \nAxio Imager.Z2 Vario. This model is recommended for situations in which \nthe microscope module is integrated into custom solutions that make use \nof the external focus drive of the customer’s own system. Once again, \nthis microscope module, together with the optional Control Box, can \nalso be controlled via the Docking Station or a PC.\n\n\nPage 8\n8\nFurther information\ncan be found at\nwww.zeiss.de/objectives\nThe Optics –\nBrilliant Vision\nAxio Imager Vario is the logical continuation of the Axio Imager family,  \nwith its tried-and-tested, renowned optical performance.\nThe illumination concept –\nInformation in brilliant quality\nYou will see your objects in brightﬁeld and darkﬁeld in proven \noutstanding quality. Stray light has been minimized and im-\naging is virtually aberration free. Excellent image contrasts \nis achieved, especially in interference contrast and even at \nhigh magniﬁcations.\nThe objective series –\nExperience Enhanced Contrast (EC)\nTo obtain comprehensive image information, you need to \nuse a wide range of objectives. With the Axio Imager Vario \nobjective series, Carl Zeiss has provided solutions for all kinds \nof requirements, in various price and performance categories.\nEC EPIPLAN Objectives\nThe economical, all-around series of objectives, which have \nbeen achromatically corrected and strain-minimized for \nimpressive-quality DIC create a ﬂat ﬁeld image for an inter-\nmediate image size of 23 mm and are available in brightﬁeld \nor brightﬁeld/darkﬁeld variants. The exit pupils are always \nidentically positioned, and Differential Interference Contrast \nin circularly polarized light is possible with all EC EPIPLAN \nobjectives using a single C-DIC prism.\nEC Epiplan-NEOFLUAR Objectives\nThe particularly high-contrast EC Epiplan-NEOFLUAR objec-\ntives, which have been corrected to a high degree and strain \nminimized, enable you to achieve sharp C-DIC and create a \nﬂat, 25 mm ﬁeld of view – ideal for displaying ﬁne color and \nstructural details, e.g. lamellae in spherulitic graphite. Avail-\nable as DIC/C-DIC, Brightﬁeld/ Darkﬁeld, Pol and LD (long \nworking distance) variants, they also offer the additional ben-\neﬁts of long working distances and high numerical apertures.\nEC Epiplan-APOCHROMAT Objectives\nThe EC Epiplan-APOCHROMAT objectives satisfy the very \nhighest demands. They are ideal for imaging color and struc-\ntural details in the sub-micrometer range and are renowned \nfor offering the best correction and highest numerical aper-\ntures. Based on ICS optics from Carl Zeiss, these innovative \nEnhanced Contrast objectives perform at the limits of what \noptics can achieve with regard to contrast and reproduction \naccuracy.\n\n\nPage 9\n9\nAxio Imager Vario also offers you \nthe convenience of being able \nto control all functions remotely.\nGreater comfort, simpler  \nchanging of contrasting  \ntechniques: The modulator  \nturret for interference  \ncontrast. \nThe tube lens turret – Increase your ﬂexibility\nWith its ﬂexible magniﬁcation range, the Axio Imager Vario \ntube lens turret offers greater variability when it comes to \nadapting the desired frame. The tube lens turret is avail-\nable in two variants: 1) Encoded: this variant allows you \nto achieve an exact magniﬁcation and automatically save \nthe scaling factors that can be derived from this in the \nimage for the analysis. Measurement results are reliable, \ndocumentable and reproducible. 2) Motorized: this variant \noffers you additional operating comfort for your system \nsolutions. And Axio Imager Vario tube lens turret offers yet \nanother advantage: the use of a focusable Bertrand lens, \nan important component for the easy observation of the \nobjective exit pupil.\nThe modulator turret – Easy to operate\nSwitching quickly and easily from one contrasting technique \nto another – the C-DIC modulator turret has been developed \nprecisely with this goal in mind. Each of the four positions \ncan be conveniently selected with a simple turn. The motor-\nized variant is particularly easy to operate. When switching \nto interference contrast, the correct module with the setting \nyou have previously deﬁned is automatically activated. If you \nswitch to brightﬁeld or darkﬁeld, the blank position will also \nbe automatically selected for fast and, above all, reproduc-\nible results.\nThe nosepiece – Flexibility in detail\nThe nosepiece provides room for up to seven objectives. You \nnow have a sufﬁcient number of objectives to use the entire \nstandard magniﬁcation series. This increases reliabilty and the \nsample throughput rate. Naturally, it is also possible to com-\nbine objectives. \nThe reﬂector turret – Switching made easy\nAll Push&amp;Click contrast modules can be stored securely in\nsix or ten positions and activated as needed using manual\nor motorized method.\n \nMore options, faster handling:\nThe reﬂector turrets with  \nPush &amp; Click Modules.\nThe motorized diaphragms – Constant image quality\nUsing the motorized aperture and luminous field dia-\nphragms you can achieve error-free, reproducible settings \nand, consequently, constant image conditions. Motorization \nguarantees you comparable results and higher productivity \nby automating the workﬂow.\nThe aperture diaphragm – Simple, but clever\nIt is often simple optimized detail that can improve your \nday-to-day work. A perfect example of this is the newly \ndeveloped aperture diaphragm from Carl Zeiss.\nThis is a slider with a motorized aperture-diaphragm re-\nvolver. The special feature is a disk with ﬁxed diaphragms \nthat rotates rather than the usual aperture iris that is opened \nand closed. Thanks to this improved component, we are \nable to guarantee you a twofold advantage: greater repeat \naccuracy and a longer life for the component.\n\n\nPage 10\n10\nTest structures, period 1.6 μm EC Epiplan-APOCHROMAT 50x / 0.95, \n8 / 0, camera-adapter 0.63x\nSurface of a silicon wafer \nrecorded with a 5x EC \nEpliplan-APOCHROMAT \nobjective. The same point \nis shown in three differ-\nent contrasting techniques: \nBrightﬁeld, darkﬁeld\nand C-DIC. Thanks to the  \ndifferent contrasting, \ndifferent details become \nvisible on the surface of the \nwafer in each case.\nBrightﬁeld\nDarkﬁeld\nC-DIC\nThe Contrasting Techniques –\nObserving in New Dimensions \nBrightﬁeld and darkﬁeld – Maximum homogeneity \nand a stray light free image background\nIn brightﬁeld the Axio Imager Vario provides homogeneous \nillumination and exceptional contrast while, in darkﬁeld, \nthe background is so dark that the technique has earned \na special name: ADF – Advanced Darkﬁeld. By minimizing \ndisturbing stray light and reducing the longitudinal color \naberration of the illumination optics, this darkﬁeld is suit-\nable for the most challenging of samples and impresses \neven when faced with the ﬁnest of structures. Switching \nbetween techniques only requires a simple turn. The mo-\ntorized stand models allow you to work particularly quickly \nand conveniently.\nC-DIC – Perfect for all structures\nCircular Differential Interference Contrast (C-DIC) is an opti-\ncal polarization procedure that, in contrast to the common \ndifferential interference contrast (DIC), works with circular, \npolarized light. The advantages of this procedure are crucial \nfor the contrasting of diverse directed object structures. \nThere is no longer the need for the preparation be turned in \nthe azimuth – with the C-DIC, a simple turn in the operating \nelement of the C-DIC slider or modulator turret is sufﬁcient \nand all successive object information can be captured. Ad-\nditionally, it also allows for every chosen fragmentation of \nevery directed structure to be adjusted. This means that with \none DIC prism, a high contrast as well as a high resolution \ncan be achieved.\nNumerous imaging options improve the visualization of your samples. \nFor demanding tasks, Carl Zeiss’ innovative C-DIC technique makes it possible  \nto achieve a clearly visible improvement in your results.\n\n\nPage 11\n11\nThe Software –\nUtilizing Modularity\nIn the ﬁelds of material research and design, requirements and areas of application are changing.\nModular and customizable, the AxioVision image analysis software, combines with Axio Imager Vario \nin order to offer you maximum ﬂexibility and capability when analyzing your images.\nAxioVision Basic\nAxioVision offers you automated control of your ZEISS \nmicroscope, allowing you to acquire, analyze and docu-\nment features such as  crystalline microstructures in your \nsamples in a single operation. Only AxioVision enables \nyou to beneﬁt from the ZVI image format, developed by \nCarl Zeiss speciﬁcally for microscopy. The quality, content \nand meaningfulness of your valuable images are retained \nwith no loss of information and with the added beneﬁt of \nintegrated documentation of the imaging conditions – es-\nsential for repeatability and the validation of your data. \nDepending on your requirements, the functionality of your \nselected system can be expanded to include various mod-\nules or adapted to individual applications, meaning that \nyou have an expandable solution for your microscopy ap-\nplications.\nMosaiX\nDeveloped to enable you to aquire images of large ob-\njects, MosaiX scans your samples in their entirety in just \none process. An overall image is then created from the \nindividual image tiles. This serves as an ideal overview im-\nage for navigating around the sample or as the basis for \nfurther analyses. From the MosaiX image you can perform \nmeasurements that cross image ﬁelds – the tiles present no \nrestriction – allowing you to gain valuable insights into the \ncontext and relationships of features of interest.\nMosaiX image of a \ngearwheel, 15 x 20 tiles. \nSimple, clearly presented \nuser interface for camera \ncontrol and image  \nacquisition.\nDetailed view: individual  \ntile of the MosaiX image.\n\n\nPage 12\nHigh-quality 1.4 megapixel\ncamera with good signal \nquality and a large dynamic \nrange\nHigh-quality 5 megapixel\ncamera with good signal \nquality\n12\nThe Cameras –\nPreserving What You See\nAxio Imager Vario provides an outstanding platform for using a wide range  \nof cameras, with the AxioCam family of Carl Zeiss forming the ideal combination.\nEntry Level\nAxioCam MRc\nAxioCam MRc5\nMid-Range\nHigh-End\nThe AxioCam family – Flexibility and performance\nAs customized components in the Carl Zeiss Systems envi-\nronment, camera, microscope and software are perfectly \nmatched to form a system solution in digital imaging that \nopens up new perspectives – in the areas of performance, \nﬂexibility and operating comfort and for both research and \nroutine applications. Axio Imager Vario microscope platform \noffers great ﬂexibility in camera use thanks to its standard-\nized camera ports (C Mount) in the stand and a complete \nassortment of camera adaptors. From digital compact cam-\neras (e.g., from Canon) up to professional, research-grade \ncameras of the Carl Zeiss AxioCam family, a wide variety \nof cameras are supported by the AxioVision image capture \nand analysis software. All digital cameras from Carl Zeiss \nare offered complete with a free entree-level version of \nAxioVision and guarantee optimal image quality.\n \nSome models are also available in a black and white ver-\nsion with an extended sensitivity range. The sophisticated \nintegration of Carl Zeiss cameras delivers important advan-\ntages: high speed, correct resolution, optimized live im-\nages or automatic exposure adjustment. All cameras in the \nAxioCam family are controlled via a uniform user interface \nin AxioVision. Naturally, you can also adapt the camera \noperation individually to the wide range of applications \nyou work on. \nEconomical CCD cameras  \nwith 1.4 or 3.3 megapixel\nAxioCam ICc\nAxioCam HRc\n13 megapixel camera with maximum \nresolution, extremely ﬂexible settings  \nand the maximum possible signal quality\nEconomical and extremely \nﬂexible 5 megapixel \nCMOS camera\nAxioCam ERc 5s\n\n\nPage 13\n13\nThe Ergonomics –\nRelax While You Work\nThe Ergophototube – Relaxed work\nFor applications where great importance is attached to ergonomics, two \ndifferent Ergophototubes are available: the Ergophototube with an upright, \nunreversed image, 44 mm continuous height adjustment and 20° viewing \nangle and the Comfort-Ergophototube with an upright, unreversed image, \n50 mm continuous height adjustment and continuous horizontal extension \nof 50 mm and 15° viewing angle.\nThe docking station – Remote Microscopy\nThe freely positionable docking station operating module makes it possible \nto control the light intensity and all motorized components of the \nAxio Imager.Z2 Vario. It has a coarse and ﬁne focus drive, a freely program-\nmable ring of buttons and a touch screen (TFT). In order to simplify complex \nsteps, all the main functions have been grouped together on the touch-screen. \nThis allows you to control all motorized components easily at the touch of \na button and to display and control the microscope status. If required, the \nintegrated light and contrast managers ensure the best possible light and \ncontrast setting. In addition to ﬁxed presettings, it is also possible to store \ncomplex procedures as individual settings and retrieve them at any time on \na user-speciﬁc basis with just the touch of a button. Axio Imager.Z2 Vario is \ntherefore ideal fore use even in a multi-user environment.\nMARC (Manual Rotary Control) – Numerous functions all in one place\nThe control unit MARC enables you to control key microscope functions, \nwhich can all be operated intuitively and extremely conveniently using just \none hand via the coarse and ﬁne drive knob and a ring of buttons.\nDepending on the microscope module connected, MARC can be used in \ndifferent ways: with Axio Imager.A2 Vario the unit is also used – in addition \nto focusing and the brightness control – to open and close the shutter to \nthe light intensity values of the nosepiece position and to switch between \nreﬂected-light and transmitted-light.\nIn the case of Axio Imager.Z2 Vario, on the other hand, MARC can be used \nas an optional control unit alongside the docking station. In this case the \nconﬁguration of the buttons reﬂects the ring of buttons on the docking sta-\ntion. Users who prefer working with two focus drive knobs can therefore \nuse MARC and the docking station at the same time in parallel. MARC can \neither be positioned freely using the tabletop base or attached to manual \nstages close to the x-y drive. The advantage of this is that the user can focus, \ncontrol brightness and move the sample with just one hand.\nFor users who want or need to sacriﬁce direct viewing into the micro-\nscope, a tube module is available without an eyepiece for viewing.\nThe Comfort-Ergotube allows the user to adopt a relaxed position \neven when working with large sample stages.\nThe docking station offers the possibility of controlling the motorized \nstage via an optional coaxial drive. \nThe MARC control unit allows the key functions to be controlled \nintuitively and extremely conveniently with just one hand.\n50 mm continuous \nheight adjustment.\n50 mm continuous \nhorizontal extension.\n\n\nPage 14\n14\nAxio Imager Vario\nTechnical Data\nComponent  \nOption\nAxio Imager.A2  \nVario\nAxio Imager.Z2  \nVario\nAxio Imager.Z2  \nVario without focus\nStand\nmanual\n+\n-\n-\nmotorized\n-\n+\n+\nControl box\n-\n+\n+\nO\nCoding (can be read out from PC) -\n+\n+\n+\nRemote control\nMARC\n+\nO\nO\nDocking Station with TFT\n-\nO\nO\nContrast manager\n-\n-\n+\n+\nLight manager\n-\n  +*\n   +**\n   +**\nTube lens turret\ncoded\nO\n-\n-\nmotorized\n-\nO\nO\nReﬂector turret\n6-pos. coded\n+\n-\n-\n6-pos. motorized\n-\nO\nO\n6-pos. motorized ACR\n-\nO\nO\nNosepiece\n6-pos. coded  POL Vario\nO\n-\n-\n6-pos. coded BD DIC Vario\nO\n-\n-\n6-pos. motorized  POL Vario\n-\nO\nO\n6-pos. motorized BD DIC\n-\nO\nO\n7-pos. motorized BD\n-\n-\nO\nModulator turret for C-DIC/TIC\nmanual\nO\nO\nO\nmotorized\n-\nO\nO\nTransmitted-light illumination\nmanual\nO\nO\nO\nDouble ﬁlter wheel  \n(transmitted light)\nmanual\nO\nO\nO\nmotorized\n-\n-\n-\nReﬂected-light illumination\nmanual\n+\n-\n-\nmotorized\n-\n+\n+\nLuminous ﬁeld diaphragm  \n(reﬂected light)\nmanual\n+\nO\nO\nmotorized\n-\nO\nO\nAperture diaphragm  \n(reﬂected light)\nmanual\nO\nO\nO\nmotorized\n-\nO\nO\nAperture diaphragm  \n(reﬂected light) with  \naperture-diaphragm revolver\nmotorized\n-\nO\nO\nDouble ﬁlter wheel  \n(reﬂected light)\nmanual\nO\nO\nO\nmotorized\n-\nO\nO\nFL attenuator\nmanual\nO\nO\nO\nmotorized\n-\nO\nO\nLight switching\nreﬂected light/transmitted light\nmanual\n     O***\n+\n+\nvia Docking Station / MARC\n     O***\n     O***\n     O***\nMixed light\nmanual\n      O****\n      O****\n      O****\nvia Docking Station\n-\n     O***\n     O***\nNosepiece focus\nmotorized,  \n10 nm step size resolution\n-\n+\n-\nmotorized,  \n25 nm step size resolution\n+\n-\n-\nApotome\n-\nO\nO\nO\nScanning stages\nDC stepper motors\nO\nO\nO\n\n\nPage 15\n15\nMicroscope module\nAxio Imager.A2  \nVario\nAxio Imager.Z2  \nVario\nAxio Imager.Z2  \nVario without focus\nHeight of sample space\n0 - 254 mm (reﬂected light, without stage)\n0 - 112 mm (reﬂected light, with stage)\n0 - 88 mm (transmitted light, with stage)\n0 - 254 mm (reﬂected light, without stage)\n0 - 112 mm (reﬂected light, with stage)\n0 - 88 mm (transmitted light, with stage)\n-\nStroke of nosepiece focus\n5 mm\n5 mm\n-\nDepth of sample space\n385 mm  (optical axis to column)\n385 mm  (optical axis to column)\n-\nMaximum travel range of stages\n300 mm x 300 mm\n300 mm x 300 mm\n-\nMaximum transmitted-light area\n200 mm x 200 mm\n200 mm x 200 mm\n-\nDimensions  \nof microscope module\n180 x 260 x 420 mm (height x width x depth)\nMass of microscope module\n17.5 to 20 kg depending on equipment\nMass of base plate and column\napprox. 78 kg\napprox. 78 kg\n-\nDimensions of base plate\n700 mm x 574 mm (width x depth)\n700 mm x 574 mm (width x depth)\n-\nEyepiece\nField of view number 23 or 25\nObjective magniﬁcation\n1x - 150x\nObjectives\nReﬂected light: \nEC EPIPLAN, EC Epiplan-NEOFLUAR, EC Epiplan-APOCHROMAT\nTransmitted light: \nN-ACHROPLAN, EC Plan-NEOFLUAR, Plan-APOCHROMAT, C-APOCHROMAT, FLUAR\nSpecial: \nLD EPIPLAN, LD EC Epiplan-NEOFLUAR\nTubes\nTube without binocular eyepiece, binocular tubes, phototubes, ergotubes and ergophototubes\nStages\nManual mechanical stages and motorized scanning stages for reﬂected light and transmitted light  \nwith travel ranges of 200 mm x 200 mm or 300 mm x 300 mm\nIllumination\n12V 100W HAL, 100W HBO, VIS LED\nContrasting techniques  \nReﬂected light: \n brightﬁeld, darkﬁeld, differential interference contrast, circular differential interference contrast,    \nsimple polarization, ﬂuorescence\nTransmitted light:  brightﬁeld, darkﬁeld, differential interference contrast, polarization, phase contrast\n + \nIncluded with stand\n O \nOptional\n - \nNot possible\n * \nLight manager manual Imager\n ** \nLight manager motorized Imager\n *** \nWith additional CAN-power supply\n **** With additional power supply\n\n\nPage 16\nInformation subject to change.\nPrinted on environmentally friendly paper\nbleached without chlorine.\n70-2-0071/e – printed 06.10\nCarl Zeiss MicroImaging GmbH\n07740 Jena, Germany\nIndustrial | Göttingen Location\nPhone : +49 551 5060 660\nTelefax : +49 551 5060 464\nE-Mail : micro@zeiss.de\nwww.zeiss.de/axioimagervario\nAt a glance – The outstanding\nfeatures of Axio Imager Vario:\n•  Stable column design\n•  Impressive sample space with vertical extension  \nup to 254 mm and sample travel range up to 300 mm\n•  Nosepiece focus with step-size resolution up to 10 nm\n•  Excellent optics with outstanding contrast \nfor the best resolution\n•  Reﬂected-light illuminator with apochromatically \ncorrected ﬁeld lens\n•  Maximum precision and reproducibility \nthanks to motorized components\n</pre></details>",
  "summary": "AxioImager Vario - long brochureOpen original PDFFull searchable text · 16 pagesRefer to the original PDF for tables, figures and page layout.Page 1 Maximum stability and precision for large samples in materials analysis and quality control. M ic ro s c o py f ro m C a r l Z ei s s Axio Imager Vario Dedicated to Large Sample Analysis Page 2 2 In materials microscopy the size of the sample space is one of the determining criteria when it comes to quality testing, quality assurance and materials…",
  "sections": [],
  "updated_at": "2026-10-17T20:52:43.954326+00:00"
}