  "title": "RUPES HE centralized turbine family",
  "kind": "reference",
  "company": "RUPES",
  "category": "Cleaning, recycling & protection",
  "parameters": {
    "Record type": "Equipment-family technical reference",
    "Family": "RUPES HE centralized turbines",
    "Process": "Extraction of micro-dust from sanding and industrial operations",
    "Standard models": "HE201, HE501 and HE901",
    "Inverter models": "HE501i, HE901i, HE1301i, HE1801i, HE1901i and HE2001i",
    "Supply": "380 V three-phase",
    "Power range": "2.2–15 kW",
    "Maximum flow range": "320–1300 m³/h",
    "Maximum vacuum range": "2900–3500 mmH₂O",
    "Dust container": "50 L",
    "Working pressure": "6 bar"
  },
  "summary": "Technical family reference for RUPES HE centralized dust-extraction turbines, including the 2.2–5.5 kW standard range and inverter-equipped 3–15 kW systems. It compares power, flow, vacuum, filter area, tool capacity and installation envelope without merging the individual models into one SKU.",
  "sections": [
    {
      "heading": "Standard 2.2–5.5 kW range",
      "rows": [
        [
          "HE201",
          "2.2 kW; 320 m³/h; 2900 mmH₂O; 4 m² filter; 2 tools; 65 dB(A); 130 kg"
        ],
        [
          "HE501",
          "3.0 kW; 390 m³/h; 2900 mmH₂O; 4 m² filter; 3 tools; 65 dB(A); 135 kg"
        ],
        [
          "HE901",
          "5.5 kW; 550 m³/h; 2900 mmH₂O; 8 m² filter; 5 tools; 70 dB(A); 170 kg"
        ]
      ]
    },
    {
      "heading": "Inverter range",
      "rows": [
        [
          "HE501i",
          "3.0 kW; 420 m³/h; 2900 mmH₂O; 4 tools"
        ],
        [
          "HE901i",
          "5.5 kW; 600 m³/h; 2900 mmH₂O; 6 tools"
        ],
        [
          "HE1301i",
          "7.5 kW; 750 m³/h; 2900 mmH₂O; 8 tools"
        ],
        [
          "HE1801i",
          "15 kW; 1000 m³/h; 3500 mmH₂O; 11 tools"
        ],
        [
          "HE1901i",
          "11 kW; 1100 m³/h; 3200 mmH₂O; 13 tools"
        ],
        [
          "HE2001i",
          "15 kW; 1300 m³/h; 3500 mmH₂O; 16 tools"
        ]
      ]
    },
    {
      "heading": "Filtration and maintenance features",
      "items": [
        "Cyclonic pre-filtration protects the cartridge stage.",
        "Rotor Jet automatic cleaning and manual cleaning are listed across the reviewed HE ranges.",
        "The standard family page reports 99.5% filtration efficiency for 0.3 µm micro-dust and up to 20,000 operating hours without maintenance; these are manufacturer-reported family claims, not site guarantees.",
        "Integrated monitoring displays pump hours, filter hours and installation notices."
      ]
    },
    {
      "heading": "System sizing",
      "items": [
        "Size by simultaneous tool count and measured airflow demand, not motor power alone.",
        "Include duct pressure loss, hose diameter, branch balancing and reserve capacity in the design calculation.",
        "Verify noise, electrical supply, compressed-air service for filter cleaning and container access at the installation location.",
        "Confirm dust combustibility and required explosion protection before choosing a non-ATEX or ATEX variant."
      ]
    }
  ],
  "updated_at": "2026-10-12 21:36:23"
}