  "title": "FilterBox 12A",
  "kind": "product",
  "company": "Nederman",
  "category": "Cleaning, recycling & protection",
  "parameters": {
    "manufacturer": "Nederman",
    "model": "FilterBox 12A",
    "maximum_airflow": "1,200 m³/h (700 CFM)",
    "filter_area": "13 m²",
    "filter_efficiency": "99%",
    "filter_class": "M6 (EN 779); MERV 11 (ASHRAE 52.2:2017)",
    "welding_fume_class": "W3 under EN 15012-1",
    "dustbin_volume": "15 L",
    "extraction_arm_diameter": "160 mm",
    "noise_level": "74 dB(A)",
    "compressed_air": "DIN ISO 8573-1 class 5/5/4 at 7 bar",
    "protection_class": "IP54",
    "installation": "indoor; mobile or floor stand",
    "cleaning": "automatic mechanical and compressed-air cleaning"
  },
  "summary": "Nederman FilterBox 12A is an automatically cleaned mobile or floor-mounted extractor for medium-to-heavier welding fumes and non-combustible grinding dust. It provides up to 1,200 m³/h through a 13 m² M6/MERV 11 filter and monitors airflow to initiate cleaning when required.",
  "sections": [
    {
      "heading": "Extraction duty",
      "paragraphs": [
        "The 12A supports medium-frequency MMA stick-welding fume, excluding high-alloy duty, and non-combustible grinding dust. The fan provides a maximum airflow of 1,200 m³/h."
      ],
      "items": [
        "W3 welding-fume performance is third-party tested under EN 15012-1.",
        "A welding-sensor clamp can start the fan automatically.",
        "Combustible dust, gas and explosive environments are excluded."
      ]
    },
    {
      "heading": "Automatic cleaning",
      "paragraphs": [
        "The control system monitors airflow and starts cleaning when flow falls below the required level. Dust versions use mechanical cleaning, while welding-fume configurations combine mechanical action with compressed air."
      ],
      "rows": [
        [
          "Filter area",
          "13 m²"
        ],
        [
          "Filter efficiency",
          "99%"
        ],
        [
          "Dust container",
          "15 L"
        ],
        [
          "Arm connection",
          "160 mm"
        ],
        [
          "Noise level",
          "74 dB(A)"
        ],
        [
          "Compressed-air supply",
          "Class 5/5/4 at 7 bar"
        ]
      ]
    },
    {
      "heading": "Installation and maintenance",
      "paragraphs": [
        "The unit can be supplied on wheels or attached to a floor stand. An optional HEPA stage adds protection against fine residual particles."
      ],
      "items": [
        "Verify the damper closes during cleaning.",
        "Maintain the IP54 casing, cartridge seals and compressed-air components.",
        "Empty the bin under controlled conditions before dust reaches the filter housing."
      ]
    }
  ],
  "updated_at": "2026-10-13T10:36:22.062Z"
}