  "title": "Fume Eliminator 840",
  "kind": "reference",
  "company": "Nederman",
  "category": "Cleaning, recycling & protection",
  "parameters": {
    "Record type": "Equipment reference",
    "Manufacturer": "Nederman",
    "Model": "Fume Eliminator 840",
    "Application": "Maintenance-welding fume source capture",
    "Installation": "Indoor",
    "Start/stop": "Manual",
    "Listed filter efficiency": "99.7%",
    "Working pressure": "22 kPa",
    "Hose length": "2.5 m",
    "Hose diameter": "44 mm",
    "Filter area": "5.3 m²",
    "Noise level": "73 dB(A)",
    "Housing material": "Sheet metal",
    "Certification": "CE"
  },
  "summary": "Nederman Fume Eliminator 840 is a portable indoor source-capture unit for maintenance welding. It connects to a 44 mm extraction hose or welding-torch nozzle and is listed with 99.7% filter efficiency, 22 kPa working pressure, 2.5 m hose length, 5.3 m² filter area and 73 dB(A) noise level.",
  "sections": [
    {
      "heading": "Purpose and layout",
      "paragraphs": [
        "Fume Eliminator 840 is designed to be carried to a maintenance-welding location and connected directly to an extraction nozzle or compatible welding-torch pickup. The manual start/stop arrangement favors short-duration source-capture work and confined access.",
        "Its usefulness depends on keeping the nozzle close enough to the fume plume without disturbing the welding process."
      ]
    },
    {
      "heading": "Captured technical data",
      "items": [
        "Filter efficiency: 99.7%.",
        "Working pressure: 22 kPa.",
        "Hose: 2.5 m long, 44 mm diameter.",
        "Filter area: 5.3 m².",
        "Noise level: 73 dB(A).",
        "Installation: indoor; housing: sheet metal; certification: CE."
      ]
    },
    {
      "heading": "Setup and performance checks",
      "items": [
        "Inspect the hose for crushing, leakage and obstruction before use.",
        "Position the nozzle at the source and verify capture throughout the welding movement.",
        "Use the 22 kPa duty point and hose geometry when checking compatibility with accessories.",
        "Monitor filter condition and declining suction; the captured page does not specify a fixed replacement interval."
      ]
    },
    {
      "heading": "Safety",
      "paragraphs": [
        "Confirm that the unit and selected filter are suitable for the actual welding-fume composition. This page does not establish suitability for combustible atmospheres, high-alloy fume or confined-space entry.",
        "Provide respiratory protection and ventilation when required by the exposure assessment. Isolate power before filter service and handle collected fume as potentially hazardous dust."
      ]
    }
  ],
  "updated_at": "2026-10-13T08:41:12.518Z"
}