  "title": "Hanatek Precision Thickness Gauge (LAB) - Rhopoint Instruments",
  "kind": "product",
  "company": "Rhopoint Instruments",
  "category": "Metrology & quality control",
  "parameters": {
    "sku": "HAN-A8041 P THICK L",
    "brand": "Hanatek",
    "category": "Precision Thickness Measurement",
    "configuration": "interchangeable heads and variable force",
    "range": "0–4000 µm",
    "resolution": "0.1 µm"
  },
  "summary": "Laboratory FT3 configuration for thickness procedures that require both interchangeable measurement heads and variable downforce. It combines programmable head motion with supplied heads, weights and a recalibration kit.",
  "sections": [
    {
      "heading": "Laboratory configuration",
      "paragraphs": [
        "The LAB version is intended for laboratories running multiple thickness methods. Its interchangeable heads allow the contact-foot geometry to be changed, while calibrated weights change the applied pressure.",
        "The listed configuration includes two measurement heads, two weights and a recalibration kit. Each method must be run with its specified head and force rather than treating all configurations as interchangeable."
      ]
    },
    {
      "heading": "Performance",
      "rows": [
        [
          "Measurement range",
          "0–4000 µm"
        ],
        [
          "Resolution",
          "0.1 µm"
        ],
        [
          "Repeatability",
          "Better than 0.4 µm under stated operating conditions"
        ],
        [
          "Reproducibility",
          "Better than 0.8 µm under stated operating conditions"
        ],
        [
          "Programmable readings",
          "Up to 500"
        ],
        [
          "Typical head parallelism",
          "Less than 1 µm"
        ],
        [
          "Non-standard head diameters",
          "6–50 mm available as configured options"
        ]
      ]
    },
    {
      "heading": "Workflow",
      "paragraphs": [
        "Install the head and mass specified for the material or standard, then verify the zero and reference gauges after a configuration change. Program down speed and dwell time to suit the specimen's compressibility.",
        "For audit-ready results, retain the head identity, total force, dwell time, speed and calibration check with each batch. This prevents data from unlike configurations being compared as though they were equivalent."
      ]
    },
    {
      "heading": "Instrument configuration",
      "rows": [
        [
          "Order code",
          "HAN-A8041 P THICK L"
        ],
        [
          "Included heads",
          "Two"
        ],
        [
          "Included weights",
          "Two"
        ],
        [
          "Included service item",
          "Recalibration kit"
        ],
        [
          "Power",
          "110/240 V, 50/60 Hz"
        ],
        [
          "Net weight",
          "10 kg maximum"
        ],
        [
          "Packed size, standard base",
          "550 × 620 × 430 mm"
        ]
      ]
    }
  ],
  "updated_at": "2026-10-14T03:38:09.686Z"
}