  "title": "Nederman 105A EX Dry Industrial Vacuum",
  "kind": "reference",
  "company": "Nederman",
  "category": "Cleaning, recycling & protection",
  "parameters": {
    "manufacturer": "Nederman",
    "model": "105A EX",
    "application": "Dry dust and granulate",
    "container_l": 67,
    "material": "AISI 316L",
    "included_accessories": [
      "Hose",
      "Floor suction nozzle"
    ],
    "certifications": [
      "CE",
      "EX"
    ],
    "atex_gas": "II 2G Ex h IIC T60°C (T6) Gb",
    "atex_dust": "II 2D Ex h IIIC T60°C (T6) Db",
    "compressed_air_consumption": "Not stated in captured page"
  },
  "summary": "Air-powered AISI 316L dry vacuum with a 67 L container for granulate and floor waste, configured for potentially explosive dust environments.",
  "sections": [
    {
      "heading": "Dry-cleaning duty",
      "paragraphs": [
        "The 105A EX is intended for granulate, floor waste and specialized dry-suction tasks. Lightweight suction equipment supports cleaning of floors, walls, beams and machinery, including work in composite and chemical-industry environments."
      ]
    },
    {
      "heading": "Mobility and construction",
      "paragraphs": [
        "The unit is described as robust yet suitable for confined spaces. A hose and floor suction nozzle are included, and the main material is AISI 316L stainless steel."
      ]
    },
    {
      "heading": "Capacity",
      "paragraphs": [
        "The captured technical data lists a 67 L collection container. No compressed-air consumption value was shown on the captured page, so that requirement is intentionally left unspecified here."
      ]
    },
    {
      "heading": "ATEX identification",
      "paragraphs": [
        "The captured marking is II 2G Ex h IIC T60°C (T6) Gb and II 2D Ex h IIIC T60°C (T6) Db. Certifications shown are CE and EX."
      ]
    },
    {
      "heading": "Use controls",
      "paragraphs": [
        "Confirm the dust explosibility data, zone classification, bonding/grounding, hose conductivity and collection/disposal method before use. ATEX suitability depends on the complete installed system and task conditions."
      ]
    }
  ],
  "updated_at": "2026-10-13 23:32:56"
}