  "title": "Minifilter",
  "kind": "reference",
  "company": "Nederman",
  "category": "Cleaning, recycling & protection",
  "parameters": {
    "Record type": "Equipment family reference",
    "Manufacturer": "Nederman",
    "Family": "MiniSeries Minifilter",
    "Application": "Wood dust collection",
    "Installation": "Indoor",
    "Available sizes": "Three",
    "Filter type": "Super Bag",
    "Filter area": "0.94 m² per bag",
    "Technical-table efficiency": "99.9%",
    "Technical-table airflow range": "3,500–5,500 m³/h",
    "Series overview maximum": "Up to 8,500 m³/h",
    "Fan characteristic": "Low-rpm operation for reduced noise"
  },
  "summary": "Nederman MiniSeries Minifilter is an enclosure-less indoor collector for wood dust, offered in three sizes. The captured technical table lists 0.94 m² filter area per bag, 99.9% efficiency and a 3,500–5,500 m³/h capacity range; the series overview separately states configurations up to 8,500 m³/h.",
  "sections": [
    {
      "heading": "System scope",
      "paragraphs": [
        "Minifilter is an enclosure-less, indoor dust-collection family intended for woodworking dust. Three sizes are described, using Super Bag filter elements and a low-speed fan arrangement to reduce operating noise.",
        "The family overview and technical table show different airflow scopes. The overview states configurations up to 8,500 m³/h, while the displayed technical row gives 3,500–5,500 m³/h. Selection should therefore use the data for the exact size and fan package."
      ]
    },
    {
      "heading": "Captured technical data",
      "items": [
        "Filter area: 0.94 m² per bag.",
        "Technical-table filter efficiency: 99.9%.",
        "Technical-table capacity range: 3,500–5,500 m³/h.",
        "Installation: indoor.",
        "Series overview: three sizes, with a stated upper capacity of 8,500 m³/h."
      ]
    },
    {
      "heading": "Selection and operation",
      "paragraphs": [
        "Size the collector from the required extraction volume, duct pressure loss and the number of simultaneous pickup points. The number of bags and fan configuration must be matched to the selected unit rather than inferred from the family maximum."
      ],
      "items": [
        "Confirm the exact airflow rating for the chosen size.",
        "Check available floor space, discharge arrangement and maintenance clearance.",
        "Monitor pressure loss and replace or clean bags under the site maintenance plan."
      ]
    },
    {
      "heading": "Wood-dust safety",
      "paragraphs": [
        "Wood dust can be combustible. Indoor installation does not by itself establish explosion safety: complete a dust-hazard assessment and provide the required isolation, venting or suppression, grounding and housekeeping controls for the actual dust.",
        "Do not apply the generic family data to explosive-service duty without the model-specific approvals and system design."
      ]
    }
  ],
  "updated_at": "2026-10-13T08:41:12.518Z"
}