  "title": "Success Case: Polishing the Inner Channel of UHP Valves │ DLyte",
  "kind": "reference",
  "company": "DLyte",
  "category": "Chemical & special polishing",
  "parameters": {
    "Record type": "Application case study",
    "Process": "Dry electropolishing with DLyte PRO500",
    "Workpiece": "Ultrahigh-purity valve inner channels",
    "Applications": "Semiconductor, chemical, food, pharmaceutical and gas systems",
    "Acceptance target": "Ra 0.15 µm",
    "Reported final roughness": "Ra <0.05 µm",
    "Recorded batch size": "64 pieces",
    "Recorded process time": "29 min per batch",
    "Revised workflow": "Machining, DLyte finishing, post-dip cleaning",
    "Former process": "Abrasive flow machining",
    "Surface requirements": "Uniform bright finish; no scratches, pits, burrs, dull areas or stains"
  },
  "summary": "For ultrahigh-purity valve passages, a DLyte PRO500 dry-electropolishing route replaced abrasive-flow finishing with machining, automated finishing and post-dip cleaning. The case records 64 valves in 29 minutes, an acceptance target of Ra 0.15 µm, and a reported final roughness below Ra 0.05 µm on internal and external surfaces.",
  "sections": [
    {
      "heading": "Application objective",
      "paragraphs": [
        "The case concerns internal passages of ultrahigh-purity and high-purity valves used in controlled gas service. Roughness and finishing defects can promote turbulence, particle generation and corrosion.",
        "The stated acceptance target was Ra 0.15 µm with uniform brightness and no scratches, pitting, burrs, dull areas or stains. The case separately reports a final roughness below Ra 0.05 µm; these are recorded as target and result, not treated as interchangeable values."
      ]
    },
    {
      "heading": "Process route and capacity",
      "paragraphs": [
        "The former abrasive-flow process required individual treatment, part-specific tooling and an additional passivation step. It also had limited access to blind holes and complex internal features.",
        "The revised route uses machining, a DLyte PRO500 finishing cycle and post-dip cleaning. A batch of 64 parts was reported finished in 29 minutes."
      ]
    },
    {
      "heading": "Inspection and qualification",
      "items": [
        "Inspect both internal and external surfaces; external gloss alone cannot confirm passage quality.",
        "Measure roughness at qualified accessible locations and use an approved method for hidden passages.",
        "Check for burrs, pits, stains and residual media after post-dip cleaning.",
        "Confirm that valve geometry and pressure-rated features remain within tolerance after finishing."
      ]
    },
    {
      "heading": "Cleanliness and safety",
      "paragraphs": [
        "Ultrahigh-purity service requires a validated downstream cleaning and cleanliness-verification procedure. The recorded polishing cycle does not by itself certify a valve for a particular gas, pressure or purity class.",
        "Maintain electrolyte condition and fixture contact, prevent alloy cross-contamination, and apply the current chemical, electrical and waste-handling controls."
      ]
    }
  ],
  "updated_at": "2026-10-13T08:34:42.874Z"
}