Mitutoyo Hardness Testers
Full searchable text · 8 pages
Refer to the original PDF for tables, figures and page layout.
Page 1 Hardness Testing Machines Product Brochure Page 2 2 Advanced Micro Vickers/Knoop Wide range of test force Precision electromagnetic controls allow the desired test force to be set between the following: HM-210: 10 gf to 1000 gf HM-220: 0.05 gf to 2000 gf Measuring microscope Designed for measuring indentation dimensions, the microscope utilizes an integrated 10X eyepiece (video camera system #125-810354A can be installed) Long working distance objectives Six (6) infinity corrected objectives are available. 10X, 20X, 50X, and 100X magnifications are used when measuring indentations; 2X and 5X are used for widefi eld observation. Touch screen controller The touch screen provides a full suite of basic functions necessary for hardness testing, including pass/fail determination, hardness value conversions, and statistical calculations. LED illumination LED illumination unit provides long service life and low power consumption. It also reduces the time lost during the light bulb replacement required with conventional illumination units. Automatic turret The positions of the indenter and objective lens can be automatically switched using the touch screen (can also be manually switched). Up to four (4) objective lenses and two (2) indenters can be installed. Video camera system 125-810354A CCD camera and 8.4" TFT monitor enable observation and measurement of indentations at high magnifi cation, thereby reducing operator error. Interfacing to external instruments Test results can be printed on a printer or output to a PC using the following: USB 2.0 interface (for data communication) for PC Digimatic interface for DP-1VR, U-WAVE, and USB-ITN Serial interface for DPU-414 Manual XY stage with digital micrometer heads During test-site positioning, the positional information is digitally displayed on both the micrometer heads and the touch screen. 1" x 1" (25 x 25 mm) standard 2" x 2" (50 x 50 mm) optional Page 3 3 Outline Drawing Easy-to-understand graphic display enables intuitive operation. Functions for converting values and compensating for curved surfaces, as well as test condition guiding functions, are all provided as standard features. Select a conversion scale, enter a setting for Pass/Fail determination, and specify external output. In addition to the test force dwell time, you can specify loading and unloading testing actions. Display test conditions and test results. Enter the specimen thickness and the presumed hardness to set a test force that satisfi es the JIS conditions. Touch Screen Controller Specifi cations Page 4 4 Wide range of test force A closed loop electromagnetic loading system features standard 10 to 1000 gf load ranges with eight (8) selectable increments. Loading rate Fixed load rate is set at 60 μm per second. Manual or motorized turret All turrets support up to two (2) indenters and three (3) infi nity corrected long working distance objectives. The 50X objective lens provides a 2.5 mm working distance. Digital display of measurement results LCD touch screen shows stage position, test procedure, statistics and scale conversions. Manual XY stage with digital micrometer heads Micro Vickers/Knoop Halogen illumination The halogen illumination system features an adjustable aperture diaphragm. During test-site positioning, the positional information is digitally displayed on both the micrometer heads and the touch screen. 1" x 1" (25 x 25 mm) standard 2" x 2" (50 x 50 mm) optional Page 5 5 Self-Leveling Vise - #125-810020 Micro Vickers/Macro Vickers/Knoop Digimatic Mini-Processor DP-1VR Printer #125-2645045A Accessories Specifi cations Clamping Vise - #125-810016 This vise secures any mounted specimen that has a measuring surface diffi cult to stabilize perpendicular to the indenter axis. This vise with 2" (51 mm) max opening comes standard with the HM-100 series. Easily print measurement data from the digimatic gage or perform statistical analysis with this device. Page 6 6 Vickers Specifi cations Wide range of test force Test force ranges from 0.2 kgf (19.61 N) to 20 kgf (196.1 N) with the HV-113 and 1 kgf (9.807 N) to 50 kgf (490.3 N) with the HV-115. Backlit LCD display Monitor display A 9" monochrome CRT is available for easy viewing of results. Motorized turret Remotely controllable, this turret supports one (1) indenter and two (2) objectives. Halogen illumination The halogen illumination system features an adjustable aperture diaphragm. The LCD panel displays: indentation size; hardness value and scale; test condition (HV indenter type, test force, load duration); OK/NG tolerance judgement; cylindrical/spherical surface compensation; and offset information. Page 7 7 Easy-to-read digital display Rockwell Testing Machines HR-430MS Twin Type (Rockwell/Rockwell Superfi cial) Also Available from Allied! HR-521 Advanced Rockwell Projected-nose indenter arm for easy reach of interior and exterior surfaces Request our full-line Rockwell Testing Machines Brochure Page 8 2376 East Pacifi ca Place, Rancho Dominguez, California 90220 USA (800) 675-1118 (US/Canada) • (310) 635-2466 (worldwide) • www.alliedhightech.com Test Blocks Knoop & Vickers Indenters Vises & Tables Specimen Holders Spare Bulbs Accessories PowerCut 10™ Abrasive Cut-Off Saw MetPrep 4™ Polishing System w/AD-5™ Fluid Dispenser Superior Quality Consumables...at a great value! Complimentary Technical & Laboratory Services...Always! Complete Line of Carl Zeiss Imaging Products For a complete list of accessories, please contact your Allied product application specialist.