PRODUCT USE INSTRUCTIONSOpen original PDFFull searchable text · 1 pagesRefer to the original PDF for tables, figures and page layout.Automatically recognized text. Verify numerical values against the original PDF.Page 1 Cure Schedule - Phenolic Preforms Au Wie) Mold HMiGe Techi PAOODUCTS iNC. Mold Size | Heat Time |Heat/Temp Cool Time | Pressure Pressure Diameter (min) (°C/°F) (min) (bar) (psi) 1"&25mm 4-5 3-4 4.0 4200 4-5 4.5 3700 1.25" & 30 mm} 150/300 1.5"&40 mm 5-6 5.0 3500 2" &50 mm 5-6…

Publication details

Manufacturer / publisherAllied High Tech Products
LanguageEnglish
Captured2026-10-17
Document typedownloads
PDF pages1
Text extractionOCR with Tesseract; verify numerical values against the original PDF
CategoryLapping, honing & superfinishing
Updated2026-10-17T21:12:06.592434+00:00
Allied High Tech published content
Source: https://www.alliedhightech.com/Media/Default/images/Phenolic%20Preforms%20Cure%20Schedule.pdf. Manufacturer claims and terminology are reproduced as source material.Explore Brochures & catalogues ↗

PRODUCT USE INSTRUCTIONS

Open original PDF

Full searchable text · 1 pages

Refer to the original PDF for tables, figures and page layout.

Automatically recognized text. Verify numerical values against the original PDF.

Page 1
Cure Schedule - Phenolic Preforms

Au Wie)

Mold

HMiGe Techi PAOODUCTS

iNC.

Mold Size | Heat Time |Heat/Temp Cool Time | Pressure

Pressure

Diameter

(min)

(°C/°F)

(min)

(bar)

(psi)

1"&25mm

4-5

3-4

4.0

4200

4-5

4.5

3700

1.25" & 30 mm}

150/300

1.5"&40 mm

5-6

5.0

3500

2" &50 mm

5-6

6.0

3200

Notes:

- All samples must be ultrasonically cleaned and then dried to remove any

debris and/or grease.

- Mold release agent must be applied every time before a mounting cycle

(200-10006 PTFE Spray is recommended).

- Duplex mounting requires 1-2 min longer heating time and 10 °C higher

heating temperature.

- Cure cycle times and temperatures may vary for non-Allied presses.

Please refer to the user's manual of your press for recommended cure

cycles.