Graphite Conductive Powder Cure Schedule
Full searchable text · 1 pages
Refer to the original PDF for tables, figures and page layout.
Automatically recognized text. Verify numerical values against the original PDF.
Page 1 Cure Schedule — Graphite-Based Conductive Mold Size Number Powder Cure Time Temp Cool Time] Mold Pressure Diameter of Scoops | Amount (g) (min) (°C/°F) (min) (psi) 1"&25 mm 1 21 3 4400 1.25" & 30 mm 1.5 31 4 4000 200/392 1.5" &40 mm 2 41 5 3800 2" & 50 mm 3.5 72 5 3500 Notes: = = For single mounts. If duplexing, 1 minute may need to be added to the cure time. Powder amount may vary depending upon the size of each sample. = All samples must be ultrasonically cleaned and dried to remove any debris and/or grease. os A mold release agent must be applied every time before a mounting cycle; Allied’s mold release for hot mounting (#200-10004) is recommended. Cure cycle times and temperatures may vary for non-Allied presses.