Page 1 M i c r o s c o p y f r o m C a r l Z e i s s KL1500 LCD and KL 2500 LCD Cold Light Sources Light Sources for Illumination and Contrasting Stereomicroscopy Stereomicroscopy needs a lot of light in a narrow space. With normal light sources this would mean a lot of heat, which is very likely to ruin your speci- mens. Cold light sources ensure intensive specimen illumination with “cold”, i.e. infrared-free light. This visible light is conducted right up to the specimen via high-quality fiber-optic light guides. Specimen-preserving cold light is a standard feature of Carl Zeiss stereo- microscopes. The performance of the KL1500 LCD and KL 2500 LCD Cold Light Sources sets new standards for stereomicroscope illumination. Salient features: • LC display of color temperature and operating modes • Continuous electronic and mechanical dimming • Stackability without com- promise on function or operating convenience • Easy lamp change – no tools required Page 2 Illuminating and Contrasting Methods Spotlight Where the stereomicros- copist needs a lot of light concentrated in a small spot, fiber-optic spot illu- minators are the answer. Annular light Annular illuminators provide circular illumination directed toward the center of the specimen, with almost no shadows. Annular slit illumi- nators allow darkfield obser- vation with either epi- or transillumination. Linear slit light Epi-illumination of the specimen surface at a very small angle makes structures of extremely low height visible. Fiber-optic light guides, whether slack or of the goose-neck type, have become standard as spot epi-illuminators in stereomicroscopy. Their flexibility allows them to be arranged at almost any position and angle relative to the specimen. With the fiber illuminator set vertically inside the focusing bracket, you can use the Transillumination Light Box for brightfield transmitted-light observation, thanks to a two-mirror deflection system. For coaxial illumination (only for Stemi SV microscopes), the illumination light is directly coupled into the stereo- microscope’s observation beam path. Thus, the size of the light spot automatically adjusts to the specimen field covered. Disturbing reflections are eliminated by an anti- reflection cap. For darkfield epi-illumination, the fibers of the annular illuminator are arranged to cast the light onto the specimen at an angle of 60° rather than vertically. This way, only the light that is diffracted by the specimen can enter the objective. For all-round darkfield transmitted light, a central stop between annular illuminator and specimen obstructs the direct light. Here again, only the light that is diffracted by the specimen and therefore carries information about it, can enter the objective. Switching from the central stop to an opal glass disk allows you to observe the specimen with brightfield transmitted light. Here, the round cross-section of the fiber bundle is con- verted into a linear (slit) arrangement. The rays emerging from the linear slit form a carpet of light covering a large specimen area and casting shadows even of the smallest elevations. 2 1 2 3 4 5 6 Page 3 3 Inclined epi-illumination casts shadows at the specimen structures, a prerequisite for three-dimensional images. Simple configuration for brightfield transmitted- light illumination. This brightfield illuminator brings out many details of flat, reflecting or polarizing surfaces. For darkfield epi-illumination, the annular illuminator is positioned close to the specimen. It is used together with a sleeve that prevents extraneous light from impairing the contrast. Especially with transmitted light, omnilateral darkfield reveals finest structures at high contrast. With incident illumination at an extremely flat angle, added contrast is produced by the high light yield and distinct shadows. 417090-9002-000 Focusing attachment to 000000-1063-292 in preparation: Focusing attachment to 417063-9901-000 417059-9901-000 Focusing attachment without filters 417060-9901-000 (no ill.) Focusing attachment and filter set 455158-9901-000 Coaxial bright-field epi-illuminator (for Objectives S 1,0x only) 455145-0000-000 Light guide with focusing attachment 417063-9901-000 Flexible light guide, 1 branch, 8/1000 mm 417052-9901-000 Goose-neck light guide, 1 branch, 4.5/600 mm 417075-9001-000 Goose-neck light guide, 2 branches, 4.5/600 mm 417075-9003-000 (no ill.) Goose-neck light guide, 3 branches, 4.5/600 mm 455146-0000-000 Universal incident-light fiber illumination system 417075-9004-000 Flexible light guide, 2 branch 4.5/1000 mm 417075-9002-000 Flexible light guide, 1 branch 3/1000 mm 000000-1063-292 Flexible light guide, 1 branch, 15/1000 mm (only for KL 2500 LCD) 000000-1004-001 (no ill.) Ring illuminator for incident-light darkfield, adjustable 417068-0000-000 Slit-ring illuminator, d=58mm 417090-9001-000 Slit-ring illuminator, d=66 mm (only for KL 2500 LCD) 417075-9011-000 Ring illuminator for incident-light darkfield 000000-1063-307 Line light S, l=50 mm Page 4 4 Illustrations on page 2: 1 Damaged gold coat, epi-illumination 2 Tragopogon blossom, brightfield transmitted light 3 Damaged gold coat, coaxial illumination 4 Damaged gold coat, darkfield epi-illumination 5 Tragopogon blossom, darkfield transmitted light 6 Fingerprint, “grayfield” epi-illumination A modular range of fiber-optic components permits the illumination to be adapted to the observation task. 00000-1063-182 (without illustration) Cold-light source KL 1500 LCD (115 V) 000000-1063-181 Cold-light source KL 1500 LCD (230V) 417053-0000-000 Halogen lamp 15 V 150 W 000000-0163-306 Conversion filter S 000000-1063-304 Filter S, yellow 000000-1063-303 Filter S, green 000000-1063-302 Filter S, red 000000-1063-301 Filter S, blue 000000-1063-317 Conversion filter, d=28 mm 000000-1063-316 Yellow filter, d=28 mm 000000-1063-315 Green filter, d=28 mm 000000-1063-314 Red filter, d=28 mm 000000-1063-313 Blue filter, d=28 mm Halogen lamp 24 V 250 W 000000-1063-184 (no ill.) Cold-light source KL 2500 LCD (115 V) 000000-1063-183 Cold-light source KL 2500 LCD (230 V) 000000-0300-271 Page 5 Features of the Cold-Light Sources 5 Switch for optimizing the illumination LC display of color temperature and operating mode Stabilized electronic brightness control Connection of remote control keypad or RS 232 interface (KL 2500 LCD only) 5-place filter wheel accommodating filters of 28 mm dia. (KL 2500 LCD only) Sturdy collet for light guides with active fiber diameters – up to 9 mm (KL1500 LCD) – up to 15 mm (KL2500 LCD) Lamp compart- ment, permits fast change of the halogen lamp without tool Mechanical brightness control without variation of the light’s color temperature Page 6 KL 1500 LCD KL 2500 LCD Weight 4.8 kg 6 kg Cooling Low-noise blower Stackability yes RS232 interface no option Filter holder Filter insert S 5-place filter wheel for 28 mm filter dia. Product certification 115 V version c CSA / UL 230 V version VDE / EMC Light data Luminous flux (Step 6) 600 lm 1300 lm Brightness control Electronic and mechanical Active fiber bundle dia. max. 9 mm max. 15 mm Electrical data Operating voltage 115 V 100 V a.c., 50/60 Hz 120 V a.c., 60 Hz Operating voltage 230 V 220 V … 240 V a.c., 50/60 Hz Enclosure Protection class II Lamp type Halogen reflector lamp Rated lamp voltage 15 V 24 V Rated lamp power 150 W 250 W Mean lamp life Step 4 1500 h Step 5 150 h Specification Subject to change. 46-0003 e/08.03 Printed on environment-friendly paper, bleached without the use of chlorine. (complies with basic requirements of Annex I to Medical Products Directive 93/42/EEC) Carl Zeiss Light Microscopy P.O.B. 40 41 37030 Göttingen GERMANY Phone: ++49 5 51 50 60 660 Telefax: ++49 5 51 50 60 464 E-Mail: micro@zeiss.de www.zeiss.de/micro For more information contact: Allied High Tech Products, Inc. 2376 E. Pacifica Place Rancho Dominguez, CA 90220 (800) 675-1118 www.alliedhightech.com