THE GLOBAL POLISHING & ABRASIVES DIRECTORYExplore database coverage ↗
POLISHX中文
POLISHX/Phenolic Mounting Powder Cure Schedule
Technical document

Phenolic Mounting Powder Cure Schedule

Phenolic Mounting Powder Cure ScheduleOpen original PDFFull searchable text · 1 pagesRefer to the original PDF for tables, figures and page layout.Automatically recognized text. Verify numerical values against the original PDF.Page 1 Cure Schedule — Phenolic Mold Size Number Powder Cure Time Temp Cool Time] Mold Pressure Diameter of Scoops | Amount (g) | (min:sec) (°C/°F) (min) (psi) 1"&25 mm 1 11-13 4 4400 1.25" & 30 mm 2 23-25 4 4000 200/392 1.5" &40 mm 2.5 28-31 3800 2" & 50 mm 4 45-50 6:30…

Publication details

Manufacturer / publisherAllied High Tech Products
LanguageEnglish
Captured2026-10-17
Document typeguides
PDF pages1
Text extractionOCR with Tesseract; verify numerical values against the original PDF
CategoryLapping, honing & superfinishing
Updated2026-10-17T21:12:06.592434+00:00
Allied High Tech published content
Source: https://www.alliedhightech.com/Media/Default/images/Phenolic%20Mounting%20Cure%20Schedule%202024.pdf. Manufacturer claims and terminology are reproduced as source material.Explore Product guides & preparation notes ↗

Phenolic Mounting Powder Cure Schedule

Open original PDF

Full searchable text · 1 pages

Refer to the original PDF for tables, figures and page layout.

Automatically recognized text. Verify numerical values against the original PDF.

Page 1
Cure Schedule — Phenolic

Mold Size

Number

Powder

Cure Time

Temp

Cool Time] Mold Pressure

Diameter

of Scoops | Amount (g) | (min:sec)

(°C/°F)

(min)

(psi)

1"&25 mm

1

11-13

4

4400

1.25" & 30 mm

2

23-25

4

4000

200/392

1.5" &40 mm

2.5

28-31

3800

2" & 50 mm

4

45-50

6:30

6:30

3500

Notes:

=

For single mounts. If duplexing, 1 minute may need to be added to the cure time.

=a

=

Powder amount may vary depending upon the size of each sample.

All samples must be ultrasonically cleaned and dried to remove any debris and/or grease.

=

A mold release agent must be applied every time before a mounting cycle; Allied’s mold release

for hot mounting (#200-10004) is recommended.

Cure cycle times and temperatures may vary for non-Allied presses.