Silicon Carbide Abrasive Belts1(US)
Also listed as: Silicon Carbide Abrasive Belts
Full searchable text · 7 pages
Refer to the original PDF for tables, figures and page layout.
Page 1 Page 1/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 59.1.0 * 1 Identification · Product name: Silicon Carbide Abrasive Belts · Part number: 50-10415 - 50-10420 50-10430 - 50-10435 50-10440 - 50-10450 · Application of the substance / the mixture Abrasive · Details of the supplier of the safety data sheet · Manufacturer/Supplier: Allied High Tech Products Inc. 16207 Carmenita Road USA-Cerritos, CA, 90703 USA info@alliedhightech.com · Information department: Product safety department · Emergency telephone number: During normal opening times: +1 (310) 635-2466 Chemtrec: +1 (202) 483-7616 2 Hazard(s) identification · Classification of the substance or mixture The product is not classified, according to the Globally Harmonized System (GHS). · Additional information: All components listed for this product are bound within the product. When handled as intended and under normal conditions of use, there is no evidence that any of the ingredients are released in amounts that pose a significant health risk. · Label elements · GHS label elements Void · Hazard pictograms Void · Signal word Void · Hazard statements Void 3 Composition/information on ingredients · Chemical characterization: Mixtures · Description: Mixture of the substances listed below with nonhazardous additions. · Hazardous components and components with occupational exposure limits: 409-21-2 silicon carbide 30-40% 1317-65-3 Limestone Acute Toxicity - Inhalation 4, H332 5-10% 14808-60-7 Quartz (SiO2) Carcinogenicity 1A, H350 <0.1% · Non-hazardous components: Polyester Film, Backing 20-30% Polymeric Resin (cured) 20-30% Proprietary Ingredient 5-10% (Contd. on page 2) Page 2 Page 2/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 1) 59.1.0 · Additional information: Product may contain many or all of the above ingredients. The specific chemical identity and/or exact percentage of the composition has been withheld as a trade secret. 4 First-aid measures · Description of first aid measures · General information: No special measures required. · After inhalation: Supply fresh air; consult doctor in case of complaints. · After skin contact: Generally the product does not irritate the skin. · After eye contact: Rinse opened eye for several minutes under running water. · After swallowing: If symptoms persist consult doctor. · Information for doctor: · Most important symptoms and effects, both acute and delayed Eye irritation Dermatitis · Indication of any immediate medical attention and special treatment needed No further relevant information available. 5 Fire-fighting measures · Extinguishing media · Suitable extinguishing agents: Use fire fighting measures that suit the environment. · Special hazards arising from the substance or mixture No further relevant information available. · Advice for firefighters · Protective equipment: No special measures required. 6 Accidental release measures · Personal precautions, protective equipment and emergency procedures Not required. · Environmental precautions: No special measures required. · Methods and material for containment and cleaning up: Dispose of the collected material according to regulations. · Reference to other sections See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information. 7 Handling and storage · Handling: · Precautions for safe handling No special measures necessary. · Information about protection against explosions and fires: No special measures required. · Conditions for safe storage, including any incompatibilities · Storage: · Requirements to be met by storerooms and receptacles: Store in a cool location. No special requirements. · Information about storage in one common storage facility: Not required. · Further information about storage conditions: Store in dry conditions. · Specific end use(s) No further relevant information available. 8 Exposure controls/personal protection · Additional information about design of technical systems: No additional data. See 7. (Contd. on page 3) Page 3 Page 3/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 2) 59.1.0 · Control parameters · Components with limit values that require monitoring at the workplace: 409-21-2 silicon carbide PEL Long-term value: 15* 5** mg/m³ fibrous dust: *total dust **respirable fraction REL Long-term value: 10* 5** mg/m³ *total dust **respirable fraction TLV Long-term value: 10* 3** mg/m³ fibrous dust:0.1 f/cc A2, nonfibrous:*inh.,**resp. 1317-65-3 Limestone PEL Long-term value: 15 mg/m³ 14808-60-7 Quartz (SiO2) PEL Long-term value: 0.05* mg/m³ *resp. dust; 30mg/m3/%SiO2+2 REL Long-term value: 0.05* mg/m³ *respirable dust; See Pocket Guide App. A TLV Long-term value: 0.025* mg/m³ *respirable particulate matter, A2 · Exposure controls · Personal protective equipment: · General protective and hygienic measures: The usual precautionary measures for handling chemicals should be followed. · Breathing equipment: Not required. Use suitable respiratory protective device in case of insufficient ventilation. · Protection of hands: Not required. · Eye protection: Not required. 9 Physical and chemical properties · Information on basic physical and chemical properties · General Information · Appearance: Form: Belt Color: According to product specification · Odor: Odorless · Odor threshold: Not determined. · pH-value: Not applicable. · Change in condition Melting point/Melting range: Undetermined. Boiling point/Boiling range: Undetermined. · Flash point: Not applicable. · Flammability (solid, gaseous): Not determined. · Decomposition temperature: Not determined. · Ignition temperature: Product is not selfigniting. · Danger of explosion: Product does not present an explosion hazard. · Explosion limits: Lower: Not determined. Upper: Not determined. (Contd. on page 4) Page 4 Page 4/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 3) 59.1.0 · Vapor pressure: Not applicable. · Density: Not determined. · Relative density Not determined. · Vapor density Not applicable. · Evaporation rate Not applicable. · Solubility in / Miscibility with Water: Insoluble. · Partition coefficient (n-octanol/water): Not determined. · Viscosity: Dynamic: Not applicable. Kinematic: Not applicable. · Solvent content: VOC content: 0.00 % Solids content: 100.0 % · Other information No further relevant information available. 10 Stability and reactivity · Reactivity No further relevant information available. · Chemical stability · Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications. · Possibility of hazardous reactions No dangerous reactions known. · Conditions to avoid No further relevant information available. · Incompatible materials: No further relevant information available. · Hazardous decomposition products: Carbon monoxide and carbon dioxide · Additional information: Hazardous decomposition products may form during combustion. 11 Toxicological information · Information on toxicological effects · Acute toxicity: · LD/LC50 values that are relevant for classification: ATE (Acute Toxicity Estimate) Inhalative LC50/4 h 33.7 mg/l (rat) 409-21-2 silicon carbide Oral LD50 >2,000 mg/kg (rat) Dermal LD50 >2,000 mg/kg (rat) 1317-65-3 Limestone Oral LD50 6,450 mg/kg (rat) Dermal LD50 >2,000 mg/kg (rat) Inhalative LC50/4 h 3 mg/l (rat) · Primary chemical irritant effect: · on the skin: No irritant effect. · on the eye: No irritating effect. · Sensitization: No sensitizing effects known. · Additional toxicological information: Abrasive skin irritant Abrasive eye irritant When used and handled according to specifications, the product does not have any harmful effects according to our experience and the information provided to us. (Contd. on page 5) Page 5 Page 5/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 4) 59.1.0 · Carcinogenic categories · IARC (International Agency for Research on Cancer) 409-21-2 silicon carbide 2A 14808-60-7 Quartz (SiO2) 1 · NTP (National Toxicology Program) 14808-60-7 Quartz (SiO2) K · OSHA-Ca (Occupational Safety & Health Administration) None of the ingredients is listed. 12 Ecological information · Toxicity · Aquatic toxicity: No further relevant information available. · Persistence and degradability No further relevant information available. · Behavior in environmental systems: · Bioaccumulative potential No further relevant information available. · Mobility in soil No further relevant information available. · Additional ecological information: · General notes: Not hazardous for water. · Results of PBT and vPvB assessment · PBT: Not applicable. · vPvB: Not applicable. · Other adverse effects No further relevant information available. 13 Disposal considerations · Waste treatment methods · Recommendation: Contact waste processors for recycling information. · Uncleaned packagings: · Recommendation: Disposal must be made according to official regulations. 14 Transport information · UN-Number · DOT, ADN, IMDG, IATA not regulated · UN proper shipping name · DOT, ADN, IMDG, IATA not regulated · Transport hazard class(es) · DOT, ADN, IMDG, IATA · Class not regulated · Packing group · DOT, IMDG, IATA not regulated · Environmental hazards: Not applicable. · Special precautions for user Not applicable. · Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code Not applicable. · UN "Model Regulation": not regulated (Contd. on page 6) Page 6 Page 6/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 5) 59.1.0 15 Regulatory information · Safety, health and environmental regulations/legislation specific for the substance or mixture · Sara · Section 355 (extremely hazardous substances): None of the ingredients is listed. · Section 313 (Specific toxic chemical listings): None of the ingredients is listed. · TSCA (Toxic Substances Control Act): All other ingredients are exempt from listing. 409-21-2 silicon carbide ACTIVE Polymeric Resin (cured) ACTIVE 1317-65-3 Limestone ACTIVE Proprietary Ingredient ACTIVE 14808-60-7 Quartz (SiO2) ACTIVE · Hazardous Air Pollutants None of the ingredients is listed. · Proposition 65 · Chemicals known to cause cancer: 14808-60-7 Quartz (SiO2) · Chemicals known to cause reproductive toxicity for females: None of the ingredients is listed. · Chemicals known to cause reproductive toxicity for males: None of the ingredients is listed. · Chemicals known to cause developmental toxicity: None of the ingredients is listed. · Chemical safety assessment: A Chemical Safety Assessment has not been carried out. 16 Other information To the best of our knowledge, the information contained herein is accurate. However, it does not describe a guarantee of product properties and does not establish a contractual legal relationship. · Department issuing SDS: Technical Services · Contact: Pablo Mendoza · Last revision / supersedes version: 06/01/2024 / 3.0 · Supersedes date: 06/01/2022 · Abbreviations and acronyms: ADR: Accord relatif au transport international des marchandises dangereuses par route (European Agreement Concerning the International Carriage of Dangerous Goods by Road) IMDG: International Maritime Code for Dangerous Goods DOT: US Department of Transportation IATA: International Air Transport Association EINECS: European Inventory of Existing Commercial Chemical Substances ELINCS: European List of Notified Chemical Substances CAS: Chemical Abstracts Service (division of the American Chemical Society) VOC: Volatile Organic Compounds (USA, EU) LC50: Lethal concentration, 50 percent LD50: Lethal dose, 50 percent PBT: Persistent, Bioaccumulative and Toxic vPvB: very Persistent and very Bioaccumulative OSHA: Occupational Safety & Health TLV: Threshold Limit Value PEL: Permissible Exposure Limit REL: Recommended Exposure Limit Acute Toxicity - Inhalation 4: Acute toxicity – Category 4 (Contd. on page 7) Page 7 Page 7/7 Safety Data Sheet acc. to OSHA HCS Printing date 07/02/2024 Last revision 06/01/2024 Version 4.0 Product name: Silicon Carbide Abrasive Belts (Contd. of page 6) 59.1.0 Carcinogenicity 1A: Carcinogenicity – Category 1A · * Data compared to the previous version altered.