Transparent Thermoplastic Powder Cure Schedule
Full searchable text · 1 pages
Refer to the original PDF for tables, figures and page layout.
Automatically recognized text. Verify numerical values against the original PDF.
Page 1 Cure Schedule — Transparent Thermoplastic Mold Size Number Powder Cure Time Temp Cool Time| Mold Pressure Diameter of Scoops | Amount (g) (min) (°C/°F) (min) (psi) 1" & 25 mm 1 13 5 200/392 4400 1.25" & 30 mm 1.5 20 6 200/392 4000 1.5"&40 mm 2 26 7 200/392 3800 2" & 50 mm 3 40 12-13 12-13 3500 130/266 Notes: For single mounts. If duplexing, 1 minute may need to be added to the cure time. Powder amount may vary depending upon the size of each sample. All samples must be ultrasonically cleaned and dried to remove any debris and/or grease. A mold release agent must be applied every time before a mounting cycle; Allied’s mold release for hot mounting (#200-10004) is recommended. Cure cycle times and temperatures may vary for non-Allied presses.