THE GLOBAL POLISHING & ABRASIVES DIRECTORY查看数据库覆盖情况 ↗
POLISHXEN
POLISHX/AUTO-M
Product & technical reference

AUTO-M

Nederman AUTO-M is a compact mechanically cleaned bag-filter family for intermittent light-duty dust collection. It uses an automatic electric shaker rather than compressed-air cleaning, supports indoor or weather-protected outdoor placement, and includes ATEX variants for St1, St2 and St3 combustible-dust applications.

Product & technical referenceNedermanCleaning, recycling & protection

Technical profile

Manufacturer / publisherNederman
Record typeDust-collector family
ManufacturerNederman
FamilyAUTO-M
Filter cleaningAutomatic electric shaking
Filter area7.5–90 m²
Maximum airflow800–10,200 m³/h
Dustbin volume75 or 150 L
Working pressure−4 to +1.5 kPa
CertificationCE; EX
CategoryCleaning, recycling & protection
Updated2026-10-13 06:36:00

Duty and construction

AUTO-M is a compact welded-steel bag collector for non-continuous duty in industrial, commercial and educational facilities. Front access is provided for maintenance, and the weather-resistant enclosure permits indoor or outdoor placement when installed to the selected version's requirements.

  • Application: dry dust collection.
  • Mechanically cleaned bag filters.
  • No compressed-air supply is required for filter cleaning.
  • 75 L or 150 L dust-bin options.

Performance envelope

The ranges cover multiple AUTO-M sizes. Final selection must match airflow, dust loading, pressure loss, temperature and the required collection efficiency.

  • Filter area: 7.5–90 m².
  • Maximum airflow: 800–10,200 m³/h.
  • Working pressure: −4 to +1.5 kPa.
  • Maximum operating temperature: +80 °C.
  • ATEX-version maximum operating temperature: +60 °C.

Combustible-dust configuration

The family includes EX-certified variants stated for St1, St2 and St3 explosive-dust categories. This capability applies only to the correctly selected and installed configuration.

  • Confirm the dust's explosion characteristics before selection.
  • Define venting, isolation, grounding and safe discharge as part of the plant design.
  • Do not apply the +80 °C general limit to an ATEX version; the published ATEX limit is +60 °C.

Cleaning and controls

An automatic electric shaker removes accumulated dust from the bags between collection cycles. Non-continuous duty allows the shaker cycle to run without process airflow disturbing dust release into the bin.

  • Interlock fan operation and shaking sequence.
  • Monitor pressure loss to establish the cleaning interval.
  • Verify that the bin is seated and sealed before restart.

Maintenance

Isolate fan and electrical power before front-access maintenance. Use dust-specific PPE and contained disposal procedures.

  • Inspect filter bags for abrasion, tears and poor seating.
  • Check shaker drive, linkages and electrical interlocks.
  • Empty the 75 L or 150 L bin before overfilling affects cleaning.
  • Inspect weather seals and corrosion protection on outdoor installations.

Files & downloads

auto-m-3e0b92dee35b416a.html ↓ auto-m-3e0b92dee35b416a.json ↓