FilterBox 10A NANO
Nederman FilterBox 10A NANO is an automatically cleaned mobile welding-fume extractor using a 17 m² nanofibre cartridge. It delivers up to 1,000 m³/h and combines MERV 15 filtration, W3 certification, pressure-drop monitoring and motorised compressed-air cleaning.
Technical specifications
| Manufacturer / publisher | Nederman |
|---|---|
| manufacturer | Nederman |
| model | FilterBox 10A NANO |
| maximum_airflow | 1,000 m³/h (600 CFM) |
| filter_area | 17 m² (183 ft²) |
| filter_efficiency | 99.9% |
| filter_class | MERV 15 (ASHRAE 52.2:2017) |
| welding_fume_class | W3 under ISO 21904-1 |
| dustbin_volume | 15 L |
| extraction_arm_diameter | 160 mm |
| noise_level | 66 dB(A) |
| protection_class | IP54 |
| installation | indoor; mobile, optional fixed mount |
| fan | N24 |
| filter_media | nanofibre |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13T10:36:22.062Z |
Applications
The 10A NANO is designed for frequent welding of aluminium, carbon steel and stainless or high-alloy steel. Its N24 fan supplies up to 1,000 m³/h through an extra-large nanofibre cartridge.
- W3 welding-fume classification is third-party certified under ISO 21904-1.
- The product is not intended for combustible dust, combustible gases or explosive atmospheres.
- A welding-sensor clamp can start the fan automatically.
Filtration and controls
The 17 m² nanofibre surface loads particulate at the media face, supporting efficient pulse cleaning and longer cleaning intervals. LED and LCD indications show pressure-drop status; low airflow triggers an audible alarm before an automatic motorised compressed-air cleaning sequence.
| Filter efficiency | 99.9% |
|---|---|
| Filter classification | MERV 15 |
| Dust container | 15 L |
| Arm connection | 160 mm |
| Optional final stage | HEPA filter |
Service checks
The automatic damper closes during cleaning, and the filter and dust bin are arranged for controlled replacement and emptying. The casing is rotomoulded plastic with IP54 protection.
- Confirm the compressed-air supply before enabling automatic cleaning.
- Observe pressure-drop indications rather than extending operation after a low-flow alarm.
- Inspect the cartridge, damper and seals whenever the 15 L bin is emptied.