Nederman FilterBox 10M is an indoor mobile or fixed extraction unit for light-to-medium welding fumes and non-combustible grinding dust. Its N24 fan provides up to 1,000 m³/h, while manual mechanical and pneumatic cleaning restores airflow through the 13 m² filter.

Technical specifications

Manufacturer / publisherNederman
manufacturerNederman
modelFilterBox 10M
maximum_airflow1,000 m³/h (600 CFM)
filter_area13 m²
filter_efficiency99%
filter_classM6 (EN 779); MERV 11 (ASHRAE 52.2:2017)
welding_fume_classW3 under EN 15012-1
dustbin_volume15 L
extraction_arm_diameter160 mm
noise_level66 dB(A)
compressed_airDIN ISO 8573-1 class 5/5/4 at 7 bar
protection_classIP54
installationindoor; mobile or fixed mount
fanN24
CategoryCleaning, recycling & protection
Updated2026-10-13T10:36:22.062Z

Extraction duty

The 10M is intended for intermittent to medium-frequency TIG, MIG and MAG welding fume, excluding high-alloy applications, and for non-combustible grinding dust. The N24 fan supports a maximum airflow of 1,000 m³/h.

  • W3 welding-fume classification is third-party tested under EN 15012-1.
  • An audible low-airflow alarm indicates when filter cleaning is required.
  • The unit must not be used for combustible dust, combustible gas or an explosive atmosphere.

Filter and collection system

The standard 13 m² cartridge is rated M6 under EN 779 and MERV 11 under ASHRAE 52.2:2017. Cleaning is initiated manually and combines mechanical action with compressed air where the welding-fume configuration requires it.

Filter efficiency99%
Dust container15 L
Arm connection160 mm
Compressed-air qualityDIN ISO 8573-1 class 5/5/4 at 7 bar
Optional final stageHEPA filter

Operation and maintenance

An automatic damper closes during cleaning to limit dust escape, and filter and bin servicing are arranged for dust-controlled handling. The integrated silencer keeps the stated sound level at 66 dB(A).

  • Check airflow and alarm operation before welding.
  • Empty the 15 L bin before material reaches the filter compartment.
  • Inspect the arm, 160 mm connection and cartridge seals for leakage after service.