FlexFilter 13 and 18 cartridge dust collector

FlexFilter 13/18 is a modular high-vacuum collector family for dry dust, granulate, grit and fume systems operating at up to 40 kPa vacuum. The galvanised-steel housing is offered in 1300 and 1800 heights with cartridge or cassette filtration and automatic pulse-jet cleaning.

Product & technical referenceNedermanCleaning, recycling & protection

Technical profile

Manufacturer / publisherNederman
manufacturerNederman
familyFlexFilter 13/18
working_vacuummaximum 40 kPa (40,000 Pa; 5.80 psi)
height_types1300 and 1800
filter_optionsUniClean cartridges or cassettes
dustbin_options50 L; 100 L; or without bin
compressed_air6 bar
operating_temperature-20 to 75 °C
housing4 mm galvanised steel sheet
cleaningautomatic pulse jet
installationindoor or outdoor
certificationCE
design_standarddesigned for ISO 21904 compliance
CategoryCleaning, recycling & protection
Updated2026-10-13T10:38:11.042Z

Configuration range

The family is selected according to airflow, dust type and dust concentration. Type 1300 and 1800 housings accept UniClean cartridges or filter cassettes, avoiding the false assumption that the two heights are individual fixed-specification SKUs.

Working vacuumUp to 40 kPa
Dust-bin options50 L, 100 L or no integral bin
Operating temperature-20 to 75 °C
Cleaning-air pressure6 bar

Construction and cleaning

The bolted housing uses 4 mm galvanised steel sheet. An integral controller activates the low-energy pulse-jet system to clean cartridges or cassettes automatically.

  • Front access covers cleaning valves, controller, compressed-air tank and filter elements.
  • Quick-release waste bins support faster emptying.
  • The system is suitable for indoor or outdoor installation.

Application controls

FlexFilter 13/18 is intended for high-vacuum systems with a high concentration of dry particulate. Stated applications include dust, granulate, grit and fumes, with the system designed toward ISO 21904 compliance.

  • Select the filter element from the actual dust characteristics and loading.
  • Do not exceed the 40 kPa working-vacuum limit or -20 to 75 °C temperature range.
  • Isolate vacuum and 6 bar compressed air before opening front-service components.