THE GLOBAL POLISHING & ABRASIVES DIRECTORYExplore database coverage ↗
POLISHX中文
POLISHX/Nederman MCP SmartFilter cartridge filtration system
Product & technical reference

Nederman MCP SmartFilter cartridge filtration system

MCP SmartFilter is a configurable cartridge collector for industrial smoke, fumes and dust. It supports indoor or outdoor installation, standalone or multiple-filter layouts, and pulse-jet cleaning. The standard version is explicitly listed as unsuitable for combustible dust.

Product & technical referenceNedermanCleaning, recycling & protection

Technical profile

Manufacturer / publisherNederman
ManufacturerNederman
Equipment familyMCP SmartFilter
Airflow range4,500–28,000 m³/h
Filter cleaningPulse jet
Construction2 mm galvanized steel
Operating temperature−20 to +60 °C
Maximum vacuum6 kPa
Maximum overpressure0 Pa; 1.5 kPa for silotop configuration
Dustbin options50 or 100 L
Compressed air60 L per cleaning pulse at 6.0 bar
InstallationIndoor or outdoor
Combustible dust suitabilityNo
CategoryCleaning, recycling & protection
Updated2026-10-13 14:42:32

Filter media and capacity

The area values are configuration ranges for different cartridge media. They are not additive and do not identify one standard build. The rounded-square cartridge geometry uses the available housing space to support high airflow in a compact footprint.

Polyester filter area30–192 m²
SC178 filter area67–422 m²
SC179 filter area32–208 m²

Control and system integration

The Insight Control Panel combines controller, operator interface and gateway functions. Its pulse-cleaning logic supports operation and monitoring, with cloud communication available through the gateway. The system is described as Insight Ready.

Available accessories include fans, inlets and dust bins. Welding, metal cutting and general industrial dust are identified applications; the selected cartridge material and collection layout remain configuration-dependent.

Standard-version limits

The standard MCP SmartFilter listing specifies a 6 kPa maximum vacuum and marks combustible-dust suitability as false. These limits should remain associated with this version; they must not be replaced with values from the separate Ex family. The positive-pressure allowance of 1.5 kPa applies only to the silotop configuration.