Nederman MCP-12S-APT Air Purification Tower
The MCP-12S-APT is an indoor ambient-air filtration tower for workshops where direct source capture is impractical or does not provide complete coverage. It combines twelve cartridge filters, pulse-jet cleaning, an integrated controller and a 10,000 m³/h maximum airflow rating.
Technical specifications
| Manufacturer / publisher | Nederman |
|---|---|
| Maximum airflow | 10,000 m³/h |
| Filter configuration | 12 high-capacity nanofiber cartridge filters |
| Filter area | 158 m² |
| Filter cleaning | Pulse jet |
| Dust bin volume | 50 L, wheeled |
| Noise level | 72 dB(A) at 1 m distance and 1.6 m height |
| Operating temperature | -20 to 70 °C |
| Maximum negative pressure | 6 kPa / 6,000 Pa |
| Installation | Indoor |
| Construction | Galvanized sheet metal |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13 |
Intended use and airflow arrangement
The tower is intended for ambient cleaning of welding fumes and suspended workshop dust. It can operate as a single unit or as part of a multi-unit layout for larger production areas.
The high configuration uses a clean-air return header that can rotate through 360 degrees and extend vertically, supporting airflow placement around cranes, large workpieces and other obstructions.
Filtration and controls
- Twelve fire-retardant nanofiber cartridges provide 158 m² of total filter area.
- Pulse-jet cleaning is controlled by the integrated controller, which also displays operating status and supports remote start/stop signals and timers.
- A variable-frequency drive can be specified for airflow control and lower energy use.
Installation and maintenance
The unit is supplied as three pre-mounted and pre-wired sections. Service points are accessible from one side, and collected dust is discharged to a 50 L wheeled bin.
The published operating envelope is -20 to 70 °C with maximum negative pressure of 6 kPa. Air-cleaning suitability and dust hazards must be assessed for the actual process before commissioning.