THE GLOBAL POLISHING & ABRASIVES DIRECTORY查看数据库覆盖情况 ↗
POLISHXEN
POLISHX/Ti Sic Fibers W 1117 Susp Plub — Composites and Reinforced Materials
Technical document

Ti Sic Fibers W 1117 Susp Plub — Composites and Reinforced Materials

Struers methods: Ti Sic Fibers W 1117 Susp Plub. Source classification: Composites and Reinforced Materials.

Publication details

Manufacturer / publisherStruers
EditionListed by source
Material familyComposites and Reinforced Materials
CategoryLapping, honing & superfinishing
Updated2026-10-17
Struers published content
Source: https://publications.struers.com/brochures/english/application-notes/methods/ti-sic-fibers-w-1117-susp-plubcomposites-and-reinforced-materials/ · Original publication: . Manufacturer claims and terminology are reproduced as source material.Explore Preparation methods ↗

Struers methods: Ti Sic Fibers W 1117 Susp Plub. Source classification: Composites and Reinforced Materials.

Original preparation method, page 1
Original method · Page 1
Searchable text transcription

The page images and original PDF preserve the table layout and notation.

Ti + SiC fibers + W
1117
Composites and Reinforced Materials
Susp. P/Lub.
Grinding
Steps
PG
FG
Surface
Type
SiC Foil #500
MD-Largo
Disc speed (rpm)
300
150
Abrasive
Type 
DP-Susp. P 9 µm
Predosing/dosing
3/6
Lubricant
Type 
Water
DP-Blue
Predosing/dosing
3/6
Force (N)
20
40
Holder direction
>>
>>
Holder speed (rpm)
150
150
Time (min)
1
6
Polishing
Steps
DP
OP
Surface
Type
MD-Dac
MD-Chem
Disc speed (rpm)
150
150
Abrasive
Type 
DP-Susp. P 3 µm
OP-S, 0.25 µm
Predosing/dosing
3/6
1/10
Lubricant
Type 
DP-Blue
Predosing/dosing
3/10
Force (N)
30
10
Holder direction
>>
><
Holder speed (rpm)
150
150
Time (min)
8
10
The method is developed to fit a standard equipment 
configuration with 30 mm specimen on 300mm disc. 
Dosing levels are valid for following equipment: 
Tegramin, AbraPol and LaboPol
For advice on how to adjust the method to fit your 
equipment, please take a look at Preparation Parameters.
The preparation time for the plane grinding (PG) step 
depends very much on the condition of the samples and 
if they are prepared as single specimens or clamped in a 
specimen holder. Please check the samples after the first 
step and repeat it if necessary.
Method comments