Air Purification Box CCD-1RC

Nederman CCD-1RC is a free-hanging indoor air-purification box for controlling light airborne dust and fumes in a contaminated air stream. Its one-way filter is rated at 95% efficiency with a maximum airflow of 2,550 m³/h.

Product & technical referenceNedermanCleaning, recycling & protection

Technical profile

Manufacturer / publisherNederman
Record typeAir-purification unit
ManufacturerNederman
ModelCCD-1RC
Maximum airflow2,550 m³/h
Filter efficiency95%
Noise level75.6 dB(A)
Maximum media temperature80 °C
Filter typeOne-way filter
CertificationCE
CategoryCleaning, recycling & protection
Updated2026-10-13 06:36:00

Application

CCD-1RC is designed for free-hanging indoor installation where light airborne dust or fumes must be recirculated through a local purification unit. It is not described as a source-capture hood or a heavy-dust collector.

  • Applications: dust and fumes.
  • Installation: indoor, free hanging.
  • Filter arrangement: one-way filter.
  • Certification: CE.

Verified performance

The published efficiency does not identify the test particle size or standard on the captured page. Suitability for a regulated contaminant therefore requires the applicable exposure limit and filtration test basis.

  • Maximum airflow: 2,550 m³/h.
  • Filter efficiency: 95%.
  • Noise level: 75.6 dB(A).
  • Maximum temperature of the filtered medium: 80 °C.

Positioning and use

  • Suspend the unit within the contaminated-air circulation zone while preserving service access.
  • Avoid placing supply or return paths where clean air immediately short-circuits back to the inlet.
  • Check that the supporting structure can carry the unit and vibration loads.
  • Use source extraction when the process requires capture before contaminants enter the breathing zone.

Filter management

The one-way filter is replaced rather than regenerated. Pressure loss, airflow or a site maintenance interval should be used to determine replacement before performance degrades.

  • Isolate electrical power before opening the unit.
  • Contain the used filter according to the collected contaminant.
  • Inspect inlet and outlet grilles and remove obstructions.
  • Confirm airflow after filter replacement.

Safety boundaries