Air Purification Box CCD-1RC
Nederman CCD-1RC is a free-hanging indoor air-purification box for controlling light airborne dust and fumes in a contaminated air stream. Its one-way filter is rated at 95% efficiency with a maximum airflow of 2,550 m³/h.
Technical profile
| Manufacturer / publisher | Nederman |
|---|---|
| Record type | Air-purification unit |
| Manufacturer | Nederman |
| Model | CCD-1RC |
| Maximum airflow | 2,550 m³/h |
| Filter efficiency | 95% |
| Noise level | 75.6 dB(A) |
| Maximum media temperature | 80 °C |
| Filter type | One-way filter |
| Certification | CE |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13 06:36:00 |
Application
CCD-1RC is designed for free-hanging indoor installation where light airborne dust or fumes must be recirculated through a local purification unit. It is not described as a source-capture hood or a heavy-dust collector.
- Applications: dust and fumes.
- Installation: indoor, free hanging.
- Filter arrangement: one-way filter.
- Certification: CE.
Verified performance
The published efficiency does not identify the test particle size or standard on the captured page. Suitability for a regulated contaminant therefore requires the applicable exposure limit and filtration test basis.
- Maximum airflow: 2,550 m³/h.
- Filter efficiency: 95%.
- Noise level: 75.6 dB(A).
- Maximum temperature of the filtered medium: 80 °C.
Positioning and use
- Suspend the unit within the contaminated-air circulation zone while preserving service access.
- Avoid placing supply or return paths where clean air immediately short-circuits back to the inlet.
- Check that the supporting structure can carry the unit and vibration loads.
- Use source extraction when the process requires capture before contaminants enter the breathing zone.
Filter management
The one-way filter is replaced rather than regenerated. Pressure loss, airflow or a site maintenance interval should be used to determine replacement before performance degrades.
- Isolate electrical power before opening the unit.
- Contain the used filter according to the collected contaminant.
- Inspect inlet and outlet grilles and remove obstructions.
- Confirm airflow after filter replacement.
Safety boundaries
The page identifies light dust and fumes but does not establish suitability for combustible dust, toxic gas, oxygen-deficient spaces or high-temperature process exhaust. These duties require a separately qualified system.