FilterBox 10A
Nederman FilterBox 10A is an automatically cleaned indoor mobile or fixed extractor for light-to-medium welding fume and grinding dust. It provides 1,000 m³/h airflow, 13 m² filter area, 99% listed efficiency, a 15 L dust bin and 66 dB(A) sound level, with W3 approval for applicable welding fume service.
Technical profile
| Manufacturer / publisher | Nederman |
|---|---|
| Record type | Equipment reference |
| Manufacturer | Nederman |
| Model | FilterBox 10A |
| Applications | TIG, MIG and MAG welding excluding high-alloy work; grinding |
| Installation | Indoor, mobile or fixed |
| Maximum airflow | 1,000 m³/h (600 CFM) |
| Filter area | 13 m² |
| Listed filter efficiency | 99% |
| Filter class | M6 (EN 779); MERV 11 (ASHRAE 52.2-2017) |
| Welding-fume approval | W3 according to EN 15012-1 |
| Dust-bin volume | 15 L |
| Extraction-arm diameter | 160 mm |
| Noise level | 66 dB(A) |
| Compressed air | DIN ISO 8573-1 class 5/5/4 at 7 bar |
| Ingress protection | IP54 |
| Excluded service | Combustible dust and combustible gases |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13T08:41:12.518Z |
Configuration and use
FilterBox 10A combines an N24 fan, automatic filter-cleaning controls and an indoor dust bin in a mobile wheeled or fixed-mount arrangement. It is intended for intermittent light-to-medium welding fume and grinding-dust capture.
The control system monitors pressure drop, warns when airflow is low and initiates a motorized cleaning sequence. Welding configurations require compressed-air cleaning; an optional HEPA stage can provide additional downstream filtration.
Technical data
- Maximum airflow: 1,000 m³/h (600 CFM).
- Filter area: 13 m²; listed efficiency: 99%.
- Dust bin: 15 L; extraction-arm diameter: 160 mm.
- Noise level: 66 dB(A); ingress protection: IP54.
- Compressed-air quality: DIN ISO 8573-1 class 5/5/4 at 7 bar.
Application limits
The captured page lists TIG, MIG and MAG welding except high-alloy work, plus grinding. W3 approval is stated according to EN 15012-1; selection still depends on fume composition, source-capture geometry and local exposure limits.
This model is explicitly excluded from environments containing combustible dust or gas and must not be used to filter combustible dust or gas.
Maintenance
- Observe the pressure-drop indication and low-airflow alarm.
- Use the correct mechanical or combined pneumatic cleaning configuration for the duty.
- Isolate the fan and compressed air before filter or bin service.
- Use the dust-free replacement and emptying procedure, and dispose of collected material according to its hazard classification.