FilterBox 12A
Nederman FilterBox 12A is an automatically cleaned mobile or floor-mounted extractor for medium-to-heavier welding fumes and non-combustible grinding dust. It provides up to 1,200 m³/h through a 13 m² M6/MERV 11 filter and monitors airflow to initiate cleaning when required.
Technical specifications
| Manufacturer / publisher | Nederman |
|---|---|
| manufacturer | Nederman |
| model | FilterBox 12A |
| maximum_airflow | 1,200 m³/h (700 CFM) |
| filter_area | 13 m² |
| filter_efficiency | 99% |
| filter_class | M6 (EN 779); MERV 11 (ASHRAE 52.2:2017) |
| welding_fume_class | W3 under EN 15012-1 |
| dustbin_volume | 15 L |
| extraction_arm_diameter | 160 mm |
| noise_level | 74 dB(A) |
| compressed_air | DIN ISO 8573-1 class 5/5/4 at 7 bar |
| protection_class | IP54 |
| installation | indoor; mobile or floor stand |
| cleaning | automatic mechanical and compressed-air cleaning |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13T10:36:22.062Z |
Extraction duty
The 12A supports medium-frequency MMA stick-welding fume, excluding high-alloy duty, and non-combustible grinding dust. The fan provides a maximum airflow of 1,200 m³/h.
- W3 welding-fume performance is third-party tested under EN 15012-1.
- A welding-sensor clamp can start the fan automatically.
- Combustible dust, gas and explosive environments are excluded.
Automatic cleaning
The control system monitors airflow and starts cleaning when flow falls below the required level. Dust versions use mechanical cleaning, while welding-fume configurations combine mechanical action with compressed air.
| Filter area | 13 m² |
|---|---|
| Filter efficiency | 99% |
| Dust container | 15 L |
| Arm connection | 160 mm |
| Noise level | 74 dB(A) |
| Compressed-air supply | Class 5/5/4 at 7 bar |
Installation and maintenance
The unit can be supplied on wheels or attached to a floor stand. An optional HEPA stage adds protection against fine residual particles.
- Verify the damper closes during cleaning.
- Maintain the IP54 casing, cartridge seals and compressed-air components.
- Empty the bin under controlled conditions before dust reaches the filter housing.