Industrial vacuum cleaner 216 E
Nederman 216 E is an indoor electric industrial vacuum for dry dust, granulate, grit, fumes and swarf. It combines cyclonic pre-separation with reverse-air-pulse filter cleaning and is listed at 460 m³/h maximum airflow, 47 L bin capacity, 2.38 m² filter area and a 7.5 m × 51 mm hose.
Technical profile
| Manufacturer / publisher | Nederman |
|---|---|
| Record type | Equipment reference |
| Manufacturer | Nederman |
| Model | 216 E |
| Duty | Dry industrial vacuuming |
| Applications | Dust, granulate, grit, fumes and swarf |
| Installation | Indoor |
| Pre-separation | Cyclonic |
| Filter cleaning | Reverse air pulse |
| Maximum airflow | 460 m³/h |
| Dust-bin volume | 47 L |
| Filter area | 2.38 m² |
| Hose length | 7.5 m |
| Hose diameter | 51 mm |
| Housing material | Sheet metal |
| Optional filtration | HEPA filter |
| Certification | CE |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13T08:41:12.518Z |
Equipment role
216 E is a portable, electrically powered dry-material collector for powder, dust, grit, granulate, fumes and swarf. The captured application examples include composite handling, construction and chemical-industry dry-material cleanup.
Cyclonic pre-separation reduces the direct solids load on the main filter, while reverse-air-pulse cleaning is used to restore filter flow.
Technical data
- Maximum airflow: 460 m³/h.
- Dust-bin capacity: 47 L.
- Filter area: 2.38 m².
- Hose: 7.5 m long, 51 mm diameter.
- Installation: indoor; housing: sheet metal; certification: CE.
- Optional downstream filtration: HEPA filter.
Use and maintenance
- Use only for dry materials within the unit's qualified duty.
- Check the cyclone, hose and inlet for accumulated material that can reduce airflow.
- Operate the reverse-air-pulse cleaning method under the prescribed sequence.
- Empty the 47 L bin before overfill and inspect seals after reassembly.
- Select the HEPA option only after confirming the required filtration class and change procedure.
Safety boundary
The captured page does not identify an explosion-protection rating. Do not collect combustible dust, hot material, reactive powder or hazardous fume without a documented suitability assessment for the entire vacuum system.
Isolate electrical power before service and control operator exposure when emptying fine or hazardous material.