Industrial vacuum cleaner 500A EX - reliable wet suction unit
Nederman 500A EX is a compressed-air industrial vacuum for liquids and sludge, built in AISI 304 stainless steel with a 208 L container, bottom drain and float overfill shutoff. The captured configuration consumes 3 m³/min compressed air and carries gas- and dust-zone ATEX markings for 60 °C maximum surface-temperature class.
Technical profile
| Manufacturer / publisher | Nederman |
|---|---|
| Record type | Equipment reference |
| Manufacturer | Nederman |
| Model | 500A EX |
| Duty | Wet extraction of liquids and sludge |
| Container system | Single container with bottom drain |
| Container volume | 208 L |
| Material | AISI 304 stainless steel |
| Overfill protection | Float ball stops suction when full |
| Compressed-air consumption | 3 m³/min |
| Certifications | CE; EX |
| ATEX gas marking | II 2G Ex h IIC T60°C (T6) Gb |
| ATEX dust marking | II 2D Ex h IIIC T60°C (T6) Db |
| Handling features | Lifting lugs and bottom drain valve |
| Category | Cleaning, recycling & protection |
| Updated | 2026-10-13T08:41:12.518Z |
Wet-collection duty
500A EX is a compressed-air vacuum for collecting flammable liquids and sludge into a single 208 L container. A bottom drain supports controlled discharge, and an internal float stops suction when the vessel reaches its liquid limit.
AISI 304 stainless-steel construction and lifting lugs support industrial handling, but compatibility must still be checked against the collected liquid.
Captured technical data
- Container volume: 208 L.
- Compressed-air consumption: 3 m³/min.
- Container material: AISI 304 stainless steel.
- Overfill control: float-operated suction stop.
- Discharge: bottom drain valve.
- Certifications shown: CE and EX.
Explosion-protection marking
The captured configuration lists II 2G Ex h IIC T60°C (T6) Gb for gas atmospheres and II 2D Ex h IIIC T60°C (T6) Db for dust atmospheres.
The marking applies only when the exact equipment configuration, accessories, bonding, compressed-air supply and collected substance remain within the certified conditions. It is not a blanket authorization for every flammable liquid.
Operation and maintenance
- Verify chemical compatibility with AISI 304, seals, hose and drain components.
- Bond and ground the complete collection path as required by the hazardous-area assessment.
- Test the float shutoff and inspect the drain valve before each wet-collection task.
- Depressurize the pneumatic supply and isolate the unit before opening or draining.
- Use the lifting lugs and rated handling method; never lift an unverified full container.