THE GLOBAL POLISHING & ABRASIVES DIRECTORYExplore database coverage ↗
POLISHX中文
POLISHX/FilterBox 10A
Product & technical reference

FilterBox 10A

Nederman FilterBox 10A is an automatically cleaned indoor mobile or fixed extractor for light-to-medium welding fume and grinding dust. It provides 1,000 m³/h airflow, 13 m² filter area, 99% listed efficiency, a 15 L dust bin and 66 dB(A) sound level, with W3 approval for applicable welding fume service.

Product & technical referenceNedermanCleaning, recycling & protection

Technical profile

Manufacturer / publisherNederman
Record typeEquipment reference
ManufacturerNederman
ModelFilterBox 10A
ApplicationsTIG, MIG and MAG welding excluding high-alloy work; grinding
InstallationIndoor, mobile or fixed
Maximum airflow1,000 m³/h (600 CFM)
Filter area13 m²
Listed filter efficiency99%
Filter classM6 (EN 779); MERV 11 (ASHRAE 52.2-2017)
Welding-fume approvalW3 according to EN 15012-1
Dust-bin volume15 L
Extraction-arm diameter160 mm
Noise level66 dB(A)
Compressed airDIN ISO 8573-1 class 5/5/4 at 7 bar
Ingress protectionIP54
Excluded serviceCombustible dust and combustible gases
CategoryCleaning, recycling & protection
Updated2026-10-13T08:41:12.518Z

Configuration and use

FilterBox 10A combines an N24 fan, automatic filter-cleaning controls and an indoor dust bin in a mobile wheeled or fixed-mount arrangement. It is intended for intermittent light-to-medium welding fume and grinding-dust capture.

The control system monitors pressure drop, warns when airflow is low and initiates a motorized cleaning sequence. Welding configurations require compressed-air cleaning; an optional HEPA stage can provide additional downstream filtration.

Technical data

  • Maximum airflow: 1,000 m³/h (600 CFM).
  • Filter area: 13 m²; listed efficiency: 99%.
  • Dust bin: 15 L; extraction-arm diameter: 160 mm.
  • Noise level: 66 dB(A); ingress protection: IP54.
  • Compressed-air quality: DIN ISO 8573-1 class 5/5/4 at 7 bar.

Application limits

The captured page lists TIG, MIG and MAG welding except high-alloy work, plus grinding. W3 approval is stated according to EN 15012-1; selection still depends on fume composition, source-capture geometry and local exposure limits.

This model is explicitly excluded from environments containing combustible dust or gas and must not be used to filter combustible dust or gas.

Maintenance

  • Observe the pressure-drop indication and low-airflow alarm.
  • Use the correct mechanical or combined pneumatic cleaning configuration for the duty.
  • Isolate the fan and compressed air before filter or bin service.
  • Use the dust-free replacement and emptying procedure, and dispose of collected material according to its hazard classification.